In vivo echo-planar imaging of rat spinal cord

被引:30
作者
Fenyes, DA [1 ]
Narayana, PA [1 ]
机构
[1] Univ Texas, Sch Med, Dept Radiol, Houston, TX 77025 USA
关键词
echo-planar imaging; spinal cord; implanted coil; autoshim;
D O I
10.1016/S0730-725X(98)00093-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An integrated approach to echo-planar imaging of rat spinal card in vivo with a small field of view (FOV) is presented. This protocol is based on a multishot interleaved echo-planar imaging (EPI) sequence and includes: 1) use of an inductively coupled implantable coil far improved signal-to-noise ratio (SNR); 2) three-dimensional (3D) automatic shimming of the magnetic field over the spinal cord; and 3) post-acquisition data processing using a multireference scan for minimizing image artifacts. Some of the practical issues in implementing this protocol are discussed. This imaging protocol will be useful in characterizing the spinal cord pathology using techniques that are otherwise time-consuming, such as diffusion tensor imaging. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1249 / 1255
页数:7
相关论文
共 28 条
  • [1] ANDERSON E, 1994, LAPACK USERS GUIDE, P140
  • [2] BALABAN R S, 1992, Magnetic Resonance Quarterly, V8, P116
  • [3] CORRECTION FOR INTENSITY FALLOFF IN SURFACE COIL MAGNETIC-RESONANCE IMAGING
    BREY, WW
    NARAYANA, PA
    [J]. MEDICAL PHYSICS, 1988, 15 (02) : 241 - 245
  • [4] IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING
    BRUDER, H
    FISCHER, H
    REINFELDER, HE
    SCHMITT, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) : 311 - 323
  • [5] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [6] CORMEN TH, 1990, INTRO ALGORITHMS, P527
  • [7] NAVIGATED DIFFUSION IMAGING OF NORMAL AND ISCHEMIC HUMAN BRAIN
    DECRESPIGNY, AJ
    MARKS, MP
    ENZMANN, DR
    MOSELEY, ME
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 720 - 728
  • [8] MAXIMIZING CONTRAST TO NOISE WITH INDUCTIVELY COUPLED IMPLANTED COILS
    FARMER, THR
    COFER, GP
    JOHNSON, GA
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 (05) : 552 - 558
  • [9] MRI CHARACTERIZATION OF DIFFUSION-COEFFICIENTS IN A RAT SPINAL-CORD INJURY MODEL
    FORD, JC
    HACKNEY, DB
    ALSOP, DC
    JARA, H
    JOSEPH, PM
    HAND, CM
    BLACK, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) : 488 - 494
  • [10] A METHOD FOR IN-VIVO HIGH-RESOLUTION MRI OF RAT SPINAL-CORD INJURY
    FORD, JC
    HACKNEY, DB
    JOSEPH, PM
    PHELAN, M
    ALSOP, DC
    TABOR, SL
    HAND, CM
    MARKOWITZ, RS
    BLACK, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) : 218 - 223