Wear and bending strain characteristics of artificial hip joint with non-glued stem and UHMWPE femur

被引:1
作者
Ishida, K
Okada, K
Hamada, Y
机构
[1] Univ Yamanashi, Interdisciplinary Grad Sch Med & Engn, Yamanashi 4008511, Japan
[2] Univ Yamanashi, Interdisciplinary Grad Sch Med & Engn, Yamanashi 4093898, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2005年 / 29卷 / 04期
关键词
artificial hip joint; non-glued condition; wear; bending strain; vibration; FFT analysis; UHMWPE femoral model;
D O I
10.1016/j.precisioneng.2004.12.008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aim of this study was to experimentally assess the effects of loosening between the stem of a cementless artificial hip joint and the femur on the wear and bending strain of the stem during the initial embedding term. The behavior of an ultrahigh-molecular-weight polyethylene (UHMWPE) femur model with this stem was then investigated. The interface between the stem and the UHMWPE femur model is either glued or not glued. Evaluation of differences between the two gluing conditions was conducted using testing equipment equipped with a reciprocating stage for an artificial hip joint. Total wear between the Co-Cr alloy head and UHMWPE socket was measured using a laser displacement meter installed in the axis direction on a main shaft of the tester. We measured the bending strain waveforms of the flexural direction, which was shown by three strain gauges on the upper, middle and lower part of the stem. The present results indicate that the rate of wear was markedly greater for non-glued stems than for the glued stems. In addition, the results indicate that the bending strain in the upper part of the non-glued stem tended to reach the maximum value of bending strain immediately after the femur model section stood upright, whereas the bending strain in the upper and middle of the glued stem tended to reach the maximum value of bending strain immediately before the femur model section stood upright. Furthermore, when the non-glued and glued stems had the same value of bending strain, the average amplitude was smaller for the non-glued stem than for the glued stem by 2-3 dB. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:396 / 403
页数:8
相关论文
共 8 条
[1]   The influence of design parameters on cortical strain distribution of a cementless titanium femoral stem [J].
Gillies, RM ;
Morberg, PH ;
Bruce, WJM ;
Turnbull, A ;
Walsh, WR .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (02) :109-114
[2]  
Higa M, 2002, J JPN SOC CLIN BIOME, V23, P167
[3]  
ISHIDA K, 2002, J JPN SOC CLIN BIOME, V23, P357
[4]   THA loading arising from increased femoral anteversion and offset may lead to critical cement stresses [J].
Kleemann, RU ;
Heller, MO ;
Stoeckle, U ;
Taylor, WR ;
Duda, GN .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (05) :767-774
[5]   PROGNOSIS OF TOTAL HIP-REPLACEMENT IN SWEDEN - FOLLOW-UP OF 92,675 OPERATIONS PERFORMED 1978-1990 [J].
MALCHAU, H ;
HERBERTS, P ;
AHNFELT, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (05) :497-506
[6]   Some properties of the bacterial wetwood (watermark) in Salix sachalinensis caused by Erwinia salicis [J].
Sakamoto, Y ;
Kato, A .
IAWA JOURNAL, 2002, 23 (02) :179-190
[7]   Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests [J].
Stolk, J ;
Verdonschot, N ;
Cristofolini, L ;
Toni, A ;
Huiskes, R .
JOURNAL OF BIOMECHANICS, 2002, 35 (04) :499-510
[8]   Hip-joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction [J].
Stolk, J ;
Verdonschot, N ;
Huiskes, R .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :917-926