The influence of design parameters on cortical strain distribution of a cementless titanium femoral stem

被引:29
作者
Gillies, RM
Morberg, PH
Bruce, WJM
Turnbull, A
Walsh, WR
机构
[1] Univ New S Wales, Prince Wales Hosp, Dept Orthopaed, Orthopaed Res Labs, Randwick, NSW 2031, Australia
[2] Orthosports, Sydney, NSW, Australia
关键词
cementless femoral hip; strain gauges; fixation parameters; cadaver study;
D O I
10.1016/S1350-4533(01)00124-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The strain distribution imposed on a femur following a total joint replacement is an important factor, in proximal bone loss due to stress shielding, and long term clinical success. This study investigated how five different design parameters of a cementless titanium femoral prosthesis influenced cortical strains. Test loads were applied and strains were measured with and without an abductor force simulation, using six human cadaveric femora. The cementless design used demonstrated significant calcar loading proximally and a similar strain distribution to the intact femur distally. Implant gross geometry was the major factor in determining the cortical strain distributions under abductor simulation in both axial and torsional loading. (C) 2002 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 29 条
[1]   A critical analysis of stress shielding evaluation of hip prostheses [J].
Cristofolini, L .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1997, 25 (4-5) :409-483
[2]   INFLUENCE OF THIGH MUSCLES ON THE AXIAL STRAINS IN A PROXIMAL FEMUR DURING EARLY STANCE IN GAIT [J].
CRISTOFOLINI, L ;
VICECONTI, M ;
TONI, A ;
GIUNTI, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (05) :617-624
[3]   CALCAR UNLOADING AFTER HIP-REPLACEMENT - A CADAVER STUDY OF FEMORAL STEM DESIGNS [J].
DJERF, K ;
GILLQUIST, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (02) :97-103
[4]  
ENGH CA, 1988, CLIN ORTHOP RELAT R, P91
[5]   AN EVALUATION OF 3 LOADING CONFIGURATIONS FOR THE INVITRO TESTING OF FEMORAL STRAINS IN TOTAL HIP-ARTHROPLASTY [J].
FINLAY, JB ;
CHESS, DG ;
HARDIE, WR ;
RORABECK, CH ;
BOURNE, RB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :749-759
[6]  
GILLIES RM, 1999, CORTICAL BONE FINAL
[7]   CLOSENESS OF FIT OF UNCEMENTED STEMS IMPROVES THE STRAIN DISTRIBUTION IN THE FEMUR [J].
HUA, J ;
WALKER, PS .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :339-346
[8]  
HUISKES R, 1995, CLIN ORTHOP RELAT R, P64
[9]   ADAPTIVE BONE-REMODELING THEORY APPLIED TO PROSTHETIC-DESIGN ANALYSIS [J].
HUISKES, R ;
WEINANS, H ;
GROOTENBOER, HJ ;
DALSTRA, M ;
FUDALA, B ;
SLOOFF, TJ .
JOURNAL OF BIOMECHANICS, 1987, 20 (11-12) :1135-1150
[10]  
HUISKES R, 1989, ORTHOPEDICS, V12, P1255