Reduced exposure using asymmetric cone beam processing for wide area detector cardiac CT

被引:18
作者
Bedayat, Arash [1 ]
Rybicki, Frank J. [1 ]
Kumamaru, Kanako [1 ]
Powers, Sara L. [1 ]
Signorelli, Jason [1 ]
Steigner, Michael L. [1 ]
Steveson, Chloe [4 ]
Soga, Shigeyoshi [1 ]
Adams, Kimberly [1 ]
Mitsouras, Dimitrios [1 ]
Clouse, Melvin [2 ]
Mather, Richard T. [3 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Appl Imaging Sci Lab, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02115 USA
[3] Toshiba Med Res Inst, Vernon Hills, IL USA
[4] Toshiba Med Syst Corp, Otawara, Tochigi, Japan
关键词
Coronary imaging; Computed tomography; Angiography; Image reconstruction; Radiation dose; ROW COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; STRATEGIES;
D O I
10.1007/s10554-011-9814-5
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
The purpose of this study was to estimate dose reduction after implementation of asymmetrical cone beam processing using exposure differences measured in a water phantom and a small cohort of clinical coronary CTA patients. Two separate 320 x 0.5 mm detector row scans of a water phantom used identical cardiac acquisition parameters before and after software modifications from symmetric to asymmetric cone beam acquisition and processing. Exposure was measured at the phantom surface with Optically Stimulated Luminescence (OSL) dosimeters at 12 equally spaced angular locations. Mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at the center plus four peripheral locations in the water phantom. To assess image quality, mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at five points within the water phantom. Retrospective evaluation of 64 patients (37 symmetric; 27 asymmetric acquisition) included clinical data, scanning parameters, quantitative plus qualitative image assessment, and estimated radiation dose. In the water phantom, the asymmetric cone beam processing reduces exposure by approximately 20% with no change in image quality. The clinical coronary CTA patient groups had comparable demographics. The estimated dose reduction after implementation of the asymmetric approach was roughly 24% with no significant difference between the symmetric and asymmetric approach with respect to objective measures of image quality or subjective assessment using a four point scale. When compared to a symmetric approach, the decreased exposure, subsequent lower patient radiation dose, and similar image quality from asymmetric cone beam processing supports its routine clinical use.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 13 条
[1]
Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[2]
George R, 2010, CIRCULATION CHICAGO
[3]
Characterization and Correction of Beam-hardening Artifacts during Dynamic Volume CT Assessment of Myocardial Perfusion [J].
Kitagawa, Kakuya ;
George, Richard T. ;
Arbab-Zadeh, Armin ;
Lima, Joao A. C. ;
Lardo, Albert C. .
RADIOLOGY, 2010, 256 (01) :111-118
[4]
Strategies for Reducing Radiation Dose in CT [J].
McCollough, Cynthia H. ;
Primak, Andrew N. ;
Braun, Natalie ;
Kofler, James ;
Yu, Lifeng ;
Christner, Jodie .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :27-+
[5]
Initial evaluation of coronary images from 320-detector row computed tomography [J].
Rybicki, Frank J. ;
Otero, Hansel J. ;
Steigner, Michael L. ;
Vorobiof, Gabriel ;
Nallamshetty, Leelakrishna ;
Mitsouras, Dimitrios ;
Ersoy, Hale ;
Mather, Richard T. ;
Judy, Philip F. ;
Cai, Tianxi ;
Coyner, Karl ;
Schultz, Kurt ;
Whitmore, Amanda G. ;
Di Carli, Marcelo F. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (05) :535-546
[6]
Prediction of coronary artery plaque progression and potential rupture from 320-detector row prospectively ECG-gated single heart beat CT angiography: Lattice Boltzmann evaluation of endothelial shear stress [J].
Rybicki, Frank J. ;
Melchionna, Simone ;
Mitsouras, Dimitris ;
Coskun, Ahmet U. ;
Whitmore, Amanda G. ;
Steigner, Michael ;
Nallamshetty, Leelakrishna ;
Welt, Fredrick G. ;
Bernaschi, Massimo ;
Borkin, Michelle ;
Sircar, Joy ;
Kaxiras, Efthimios ;
Succi, Sauro ;
Stone, Peter H. ;
Feldman, Charles L. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 :289-299
[7]
Lower radiation dose coronary CT angiography with new imaging technologies [J].
Rybicki, Frank J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 :149-151
[8]
National survey of doses from CT in the UK: 2003 [J].
Shrimpton, P. C. ;
Hillier, M. C. ;
Lewis, M. A. ;
Dunn, M. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (948) :968-980
[9]
Iodinated Contrast Opacification Gradients in Normal Coronary Arteries Imaged With Prospectively ECG-Gated Single Heart Beat 320-Detector Row Computed Tomography [J].
Steigner, Michael L. ;
Mitsouras, Dimitrios ;
Whitmore, Amanda G. ;
Otero, Hansel J. ;
Wang, Chunliang ;
Buckley, Orla ;
Levit, Noah A. ;
Hussain, Alia Z. ;
Cai, Tianxi ;
Mather, Richard T. ;
Smedby, Orjan ;
DiCarli, Marcelo F. ;
Rybicki, Frank J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (02) :179-186
[10]
Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography [J].
Steigner, Michael L. ;
Otero, Hansel J. ;
Cai, Tianxi ;
Mitsouras, Dimitrios ;
Nallamshetty, Leelakrishna ;
Whitmore, Amanda G. ;
Ersoy, Hale ;
Levit, Noah A. ;
Di Carli, Marcelo F. ;
Rybicki, Frank J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (01) :85-90