Initial evaluation of coronary images from 320-detector row computed tomography

被引:440
作者
Rybicki, Frank J. [1 ]
Otero, Hansel J. [1 ]
Steigner, Michael L.
Vorobiof, Gabriel
Nallamshetty, Leelakrishna
Mitsouras, Dimitrios [1 ]
Ersoy, Hale [1 ]
Mather, Richard T. [2 ]
Judy, Philip F. [1 ]
Cai, Tianxi [1 ,3 ]
Coyner, Karl
Schultz, Kurt [2 ]
Whitmore, Amanda G. [1 ]
Di Carli, Marcelo F.
机构
[1] Brigham & Womens Hosp, Appl Imaging Sci Lab, Dept Radiol, Boston, MA 02115 USA
[2] Toshiba Amer Med Syst, Tustin, CA USA
[3] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
关键词
computed tomography; coronary angiography; coronary vessels; image enhancement; radiation dosage;
D O I
10.1007/s10554-008-9308-2
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Purpose To evaluate image quality and contrast opacification from coronary images acquired from 320-detector row computed tomography (CT). Patient dose is estimated for prospective and retrospective ECG-gating; initial correlation between 320-slice CT and coronary catheterization is illustrated. Methods Retrospective image evaluation from forty consecutive patients included subjective assessment of image quality and contrast opacification (80 ml iopamidol 370 mg I/ml followed by 40 ml saline). Region of interest opacification measurements at the ostium and at 2.5 mm diameter were used to determine the gradient of contrast opacification (defined as the proximal minus distal HU measurements) in coronary arteries imaged in a single heartbeat. Estimated effective dose was compared for prospective versus retrospective ECG-gating, two body mass index categories (30 kg/m(2) cutoff), and single versus two heartbeat acquisition. When available, CT findings were correlated with those from coronary catheterization. Results Over 89% of arterial segments (15 segment model) had excellent image quality. The most common reason for image degradation was cardiac motion. One segment in one patient was considered unevaluable. Contrast opacification was almost universally considered excellent. The mean Hounsfield units (HU) was greater than 350; the coronary contrast opacification gradient was 30-50 HU. Patient doses were greater for retrospective ECG-gating, larger patients, and those imaged with two heartbeats. For the most common (n = 25) protocol (120 kV, 400 mA, prospective ECG-gating, 60-100% phase window, 16 cm craniocaudal coverage, single heartbeat), the mean dose was 6.8 +/- 1.4 mSv. All CT findings were confirmed in the four patients who underwent coronary catheterization. Conclusion Initial 320-detector row coronary CT images have consistently excellent quality and iodinated contrast opacification. These patients were scanned with conservative protocols with respect to iodine load, prospective ECG-gating phase window, and craniocaudal coverage. Future work will focus on lowering contrast and radiation dose while maintaining image quality.
引用
收藏
页码:535 / 546
页数:12
相关论文
共 47 条
[1]
Austen W G, 1975, Circulation, V51, P5
[2]
Baur LHB, 2008, INT J CARDIOVAS IMAG, V24, P343, DOI 10.1007/s10554-007-9280-2
[3]
Accuracy and rate of coronary artery segment visualization with CT angiography for the non-invasive detection of coronary artery stenoses [J].
Bordeleau, Edith ;
Lamonde, Alexandre ;
Prenovault, Julie ;
Belblidia, Assia ;
Cote, Gilles ;
Lesperance, Jacques ;
Soulez, Gilles ;
Chartrand-Lefebvre, Carl .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (06) :771-780
[4]
Dual-source CT with improved temporal resolution in assessment of left ventricular function: A pilot study [J].
Brodoefel, Harald ;
Kramer, Ulrich ;
Reimann, Anja ;
Burgstahler, Christof ;
Schroeder, Stephen ;
Kopp, Andreas ;
Heuschmid, Martin .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (05) :1064-1070
[5]
Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients [J].
d'Agostino, A. G. ;
Remy-Jardin, M. ;
Khalil, C. ;
Delannoy-Deken, V. ;
Flohr, T. ;
Duhamel, A. ;
Remy, J. .
EUROPEAN RADIOLOGY, 2006, 16 (10) :2137-2146
[6]
Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients [J].
Delhaye, Damien ;
Remy-Jardin, Martine ;
Salem, Randa ;
Teisseire, Antoine ;
Khalil, Chadi ;
Delannoy-Deken, Valerie ;
Duhamel, Alain ;
Remy, Jacques .
EUROPEAN RADIOLOGY, 2007, 17 (04) :902-910
[7]
Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients [J].
Delhaye, Damien ;
Remy-Jardin, Martine ;
Rozel, Celine ;
Dusson, Catherine ;
Wurtz, Alain ;
Delannoy-Deken, Valerie ;
Duhamel, Alain ;
Remy, Jacques .
EUROPEAN RADIOLOGY, 2007, 17 (03) :591-602
[8]
Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753
[9]
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[10]
Magnitude and effects of x-ray scatter in a 256-slice CT scanner [J].
Endo, Masahiro ;
Mori, Shinichiro ;
Tsunoo, Takanori ;
Miyazaki, Hiroaki .
MEDICAL PHYSICS, 2006, 33 (09) :3359-3368