Fabrication and electrochemical behavior of hemoglobin modified carbon ionic liquid electrode

被引:24
作者
Sun, Wei [1 ,2 ]
Gao, Ruifang [1 ]
Li, Xiaoqing [1 ]
Wang, Dandan [1 ]
Yang, Maoxia [1 ]
Jiao, Kui [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Minist Educ, Key Lab Eco Chem Engn, Qingdao 266042, Peoples R China
[2] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
hemoglobin; room temperature ionic liquid; 1-butyl-3-methylimidazolium hexafluorophosphate; direct electrochemistry; electrocatalysis;
D O I
10.1002/elan.200704131
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new hemoglobin (Hb) and room temperature ionic liquid modified carbon paste electrode was constructed by mixing Hb with 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6) and graphite powder together. The Hb modified carbon ionic liquid electrode (Hb-CILE) was further characterized by FT-IR spectra, scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Hb in the carbon ionic liquid electrode remained its natural structure and showed good direct electrochemical behaviors. A pair of well-defined quasireversible redox peaks appeared with the apparent standard potential (E') as -0.334 (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer number (n), the electron transfer coefficient (alpha) and the heterogeneous electron transfer kinetic constant (k(s)) of the electrode reaction were calculated with the results as 1.2, 0.465 and 0.434 s(-1), respectively. The fabricated Hb-CILE exhibited excellent electrocatalytic activity to the reduction of H2O2. The calibration range for H2O2 quantitation was between 8.0 x 10(-6) mol/L and 2.8 x 10(-4) mol/L with the linear regression equation as I-ss (mu A) = 0.12 C (mu mol/L) + 0.73 (n = 18, gamma = 0.997) and the detection limit as 1.0 x 10(-6) mol/L (3 sigma). The apparent Michaelis-Menten constant (K-M(app)) of Hb in the modified electrode was estimated to be 1.103 mmol/L. The surface of this electrochemical sensor can be renewed by a simple polishing step and showed good reproducibility.
引用
收藏
页码:1048 / 1054
页数:7
相关论文
共 45 条
[1]  
ARMSTRONG FA, 1994, ACCOUNTS CHEM RES, V3, P313
[2]  
Bard A. J., 1980, ELECTROCHEMICAL METH
[3]   Use of room temperature ionic liquids in gas sensor design [J].
Buzzeo, MC ;
Hardacre, C ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4583-4588
[4]  
COMPTON DL, 2002, J ELECTROANAL CHEM, V71, P520
[5]   Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases (CLEC®) [J].
de Mattos, IL ;
Lukachova, LV ;
Gorton, L ;
Laurell, T ;
Karyakin, AA .
TALANTA, 2001, 54 (05) :963-974
[6]   DIRECT AND INDIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND REDOX PROTEINS [J].
FREW, JE ;
HILL, HAO .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1988, 172 (02) :261-269
[7]   Effect of silver nanoparticles on the electron transfer reactivity and the catalytic activity of myoglobin [J].
Gan, X ;
Liu, T ;
Zhong, J ;
Liu, XJ ;
Li, GX .
CHEMBIOCHEM, 2004, 5 (12) :1686-1691
[8]   Protein electrochemistry using aligned carbon nanotube arrays [J].
Gooding, JJ ;
Wibowo, R ;
Liu, JQ ;
Yang, WR ;
Losic, D ;
Orbons, S ;
Mearns, FJ ;
Shapter, JG ;
Hibbert, DB .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (30) :9006-9007
[9]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[10]   Driving forces for layer-by-layer self-assembly of films of SiO2 nanoparticles and heme proteins [J].
He, PL ;
Hu, NF ;
Rusling, JF .
LANGMUIR, 2004, 20 (03) :722-729