Acetabular Reconstruction with Impaction Bone-Grafting and a Cemented Cup in Patients Younger than Fifty Years Old A Concise Follow-up, at Twenty to Twenty-eight Years, of a Previous Report

被引:49
作者
Busch, Vincent J. J. F. [1 ]
Gardeniers, Jean W. M. [1 ]
Verdonschot, Nico [1 ]
Slooff, Tom J. J. H. [1 ]
Schreurs, B. Willem [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Orthopaed 357, NL-6500 HB Nijmegen, Netherlands
关键词
TOTAL HIP-ARTHROPLASTY; REVISION; REPLACEMENT; COMPONENT;
D O I
10.2106/JBJS.I.01532
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
In a previous report, we presented our results of forty-two acetabular reconstructions, performed with use of impaction bone-grafting and a cemented polyethylene cup, in thirty-seven patients who were younger than fifty years and had a minimum of fifteen years of follow-up. The present update study shows the results after twenty to twenty-eight years. Eight additional cups had to be revised-four because of aseptic loosening, three because of wear, and one during a revision of the stem. Three additional cups were considered loose on radiographs. Survivorship of the acetabular reconstructions, with an end point of revision for any reason, was 73% after twenty years and 52% after twenty-five years. With revision for aseptic loosening as the end point, survival was 85% after twenty years and 77% after twenty-five years; for signs of loosening on radiographs, survival was 71% at twenty years and 62% at twenty-five years. In conclusion, our previous results have declined but the technique of using impacted morselized bone graft and a cemented cup is useful for the purpose of restoring bone stock in young patients whose acetabular defects require primary or revision total hip arthroplasty.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 14 条
[1]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[2]
CONN R A, 1985, Orthopaedic Transactions, V9, P451
[3]
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[4]
Questionnaire on the perceptions of patients about total hip replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Carr, A ;
Murray, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :185-190
[5]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports [J].
Della Valle, Craig J. ;
Mesko, Nathan W. ;
Quigley, Laura ;
Rosenberg, Aaron G. ;
Jacobs, Joshua J. ;
Galante, Jorge O. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (05) :1130-1135
[7]
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
[8]
Twenty-five-year results after charnley total hip arthroplasty in patients less than fifty years old - A concise follow-up of a previous report [J].
Keener, JD ;
Callaghan, JJ ;
Goetz, DD ;
Pederson, DR ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (06) :1066-1072
[9]
Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years [J].
Lachiewicz, PF ;
Poon, ED .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07) :980-984
[10]
EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528