摘要
Using computer simulations and high-resolution fMRI experiments in humans (n = 6) and rats (n = 8) we investigated to what extent BOLD fMRI temporal resolution is limited by dispersion in the venous vasculature. For this purpose, time-to-peak (TTP) and full-width at half-maximum (FWHM) of the BOLD impulse response (IR) function were determined. In fMRI experiments, a binary in-sequence probe method was used to obtain high-sensitivity model-free single-pixel estimates of IR. Simulations of posteapillary flow suggested that flow-related dispersion leads to a TTP and FWHM increase, which can amount to several seconds in larger pial veins. fMRI experiments showed substantial spatial variation in IR timing within human visual cortex, together with a correlation between TTP and FWHM. Averaged across the activated regions and across subjects, TTP and FWHM were 4.51 +/- 0.52 and 4.04 +/- 0.42 s, respectively. In regions of interest (ROI) weighted toward the larger venous structures, TTP and FWHM increased to 5.07 +/- 0.64 and 4.32 +/- 0.48 s, respectively. In rat somatosensory cortex, TTP and FWHM were substantially shorter than in humans (2.73 +/- 0.60 and 2.28 +/- 0.63 s, respectively). These results are consistent with a substantial macrovascular dispersive contribution to BOLD IR in humans, and furthermore suggest that neurovascular coupling is a relatively rapid process, with a resolution below 2.3 s FWHM. Published by Elsevier Inc.
引用
收藏
页码:667 / 677
页数:11
相关论文
共 63 条
[1]   The variability of human, BOLD hemodynamic responses [J].
Aguirre, GK ;
Zarahn, E ;
D'Esposito, M .
NEUROIMAGE, 1998, 8 (04) :360-369
[2]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[3]   Hemodynamic response in the unanesthetized rat: Intrinsic optical imaging and spectroscopy of the barrel cortex [J].
Berwick, J ;
Martin, C ;
Martindale, J ;
Jones, M ;
Johnston, D ;
Zheng, Y ;
Redgrave, P ;
Mayhew, J .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (06) :670-679
[4]   Scalable multichannel MRI data acquisition system [J].
Bodurka, J ;
Ledden, PJ ;
van Gelderen, P ;
Chu, RX ;
de Zwart, JA ;
Morris, D ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :165-171
[5]   Linear systems analysis of functional magnetic resonance imaging in human V1 [J].
Boynton, GM ;
Engel, SA ;
Glover, GH ;
Heeger, DJ .
JOURNAL OF NEUROSCIENCE, 1996, 16 (13) :4207-4221
[6]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[7]  
Buckner RL, 1998, HUM BRAIN MAPP, V6, P373, DOI 10.1002/(SICI)1097-0193(1998)6:5/6<373::AID-HBM8>3.0.CO
[8]  
2-P
[9]   Efficient design of event-related fMRI experiments using M-sequences [J].
Buracas, GT ;
Boynton, GM .
NEUROIMAGE, 2002, 16 (03) :801-813
[10]   Two-photon imaging of capillary blood flow in olfactory bulb glomeruli [J].
Chaigneau, E ;
Oheim, M ;
Audinat, E ;
Charpak, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (22) :13081-13086