Bienzyme HRP-GOx-modified gold nanoelectrodes for the sensitive amperometric detection of glucose at low overpotentials

被引:78
作者
Delvaux, M
Walcarius, A
Demoustier-Champagne, S
机构
[1] Catholic Univ Louvain, Unite Phys & Chim Hauts Polymeres, B-1348 Louvain, Belgium
[2] Univ Nancy 1, CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
关键词
enzyme-modified gold nanoelectrodes; horseradish peroxidase; glucose oxidase; glucose amperometric detection;
D O I
10.1016/j.bios.2004.07.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gold nanotubular electrode ensembles were prepared by using electroless deposition of the metal within the pores of polycarbonate track-etched membranes. Mono-enzyme (GOx) and monolayer/bilayer bienzyme (GOx/HRP) bioelectrodes were prepared by immobilizing the enzymes onto gold nanotubes surfaces modified with mercaptoethylamine. Batch amperometric responses to glucose for the different bioelectrodes were determined and compared. The response of the two geometries (monolayer and bilayer) of the bienzyme electrodes was shown to vary with regard to sensitivity at detection potentials above 0 V. On the contrary, at detection potentials below 0 V, no noticeable influence of the configuration of the bienzyme on the response intensity was observed. The mono-enzyme (650 muA mM(-1) in benzoquinone (BQ) at -0.8 V versus Ag/AgCl) and the two bienzyme bioelectrodes (+/-400 muA mM(-1) in hydroquinone (H(2)Q) at -0.2 V versus Ag/AlCl) display remark-able sensitivities compared to a classical GOx-modified gold macroelectrode (13 muA mM(-1) in BQ at -0.8 V versus Ag/AgCl). A remark-able feature of the bienzyme electrodes is the possibility to detect glucose at very low applied potentials where the noise level and interferences from other electro-oxidizable compounds are minimal. Another important characteristic of the monolayer bienzyme electrode is the possible existence of a direct electronic communication between HRP and the transducer surface. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1587 / 1594
页数:8
相关论文
共 32 条
[1]   TEMPLATE SYNTHESIS OF METAL MICROTUBULE ENSEMBLES UTILIZING CHEMICAL, ELECTROCHEMICAL, AND VACUUM DEPOSITION TECHNIQUES [J].
BRUMLIK, CJ ;
MENON, VP ;
MARTIN, CR .
JOURNAL OF MATERIALS RESEARCH, 1994, 9 (05) :1174-1183
[2]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[3]   MEDIATORLESS ELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE AT GRAPHITE-ELECTRODES CHEMICALLY-MODIFIED WITH PEROXIDASES [J].
CSOREGI, E ;
JONSSONPETTERSSON, G ;
GORTON, L .
JOURNAL OF BIOTECHNOLOGY, 1993, 30 (03) :315-337
[4]   One-step fabrication of a bienzyme glucose sensor based on glucose oxidase and peroxidase immobilized onto a poly(pyrrole) modified glassy carbon electrode [J].
DeBenedetto, GE ;
Palmisano, F ;
Zambonin, PG .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (10) :1001-1008
[5]   Flow injection amperometric detection at enzyme-modified gold nanoelectrodes [J].
Delvaux, M ;
Demoustier-Champagne, S ;
Walcarius, A .
ELECTROANALYSIS, 2004, 16 (03) :190-198
[6]   Immobilisation of glucose oxidase within metallic nanotubes arrays for application to enzyme biosensors [J].
Delvaux, M ;
Demoustier-Champagne, S .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (07) :943-951
[7]   Preparation of polymeric and metallic nanostructures using a template-based deposition method [J].
Demoustier-Champagne, S ;
Delvaux, M .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2001, 15 (1-2) :269-271
[8]   Direct electron transfer based tri-enzyme electrode for monitoring of organophosphorus pesticides [J].
DiehlFaxon, J ;
Ghindilis, AL ;
Atanasov, P ;
Wilkins, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) :448-457
[9]   Self-assembled monolayers: a versatile tool for the formulation of bio-surfaces [J].
Ferretti, S ;
Paynter, S ;
Russell, DA ;
Sapsford, KE ;
Richardson, DJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (09) :530-540
[10]  
Ferri T, 2001, ELECTROANAL, V13, P1198, DOI 10.1002/1521-4109(200110)13:14<1198::AID-ELAN1198>3.0.CO