Octadecyl immobilized surface for precipitate collection with a renewable microcolumn in a lab-on-valve coupled to an electrothermal atomic absorption spectrometer for ultratrace cadmium determination

被引:68
作者
Wang, Y [1 ]
Wang, JH [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
关键词
D O I
10.1021/ac050638z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Octadecyl immobilized surface was, for the first time, proved to be a superb precipitate-collecting medium. Surface charge effect was assumed to dominate the adsorption of cadmium hydroxide precipitate, facilitated by electrostatic interaction between the negatively charged C18 bead surface and positively charged cadmium hydroxide clusters. Residual silanol groups on the C18-immobilized silica surface did not contribute to precipitate adsorption. A novel procedure for ultratrace cadmium preconcentration was proposed by incorporating a renewable microcolumn in a lab-on-valve system. Cd(OH)(2) precipitate was adsorbed onto the C 18 surface, which was afterward eluted with 20 mu L of nitric acid (1%) and quantified with detection by electrothermal atomic absorption spectrometry. An enrichment factor of 28 and a limit of detection of 1.7 ng L-1, along with a sampling frequency of 13 h(-1) were obtained with a sample consumption of 600 mu L within the concentration range of 0.01-0.2 mu g L-1, achieving a precision of 2.1% RSD at the 0.05 mu g L-1 level. The enrichment factor was further enhanced to 44 by increasing the sample volume to 1200 mu L. The procedure was validated by analyzing cadmium in three certified reference materials, that is, river sediment (CRM 320), sea lettuce (CRM 279), and frozen cattle blood (GBW 09140). Good agreement between the obtained results and the certified values was achieved.
引用
收藏
页码:5396 / 5401
页数:6
相关论文
共 32 条
[1]  
Alonso EIV, 2001, J ANAL ATOM SPECTROM, V16, P293
[2]   Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) :1400-1403
[3]   Trace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1349-1356
[4]   Determination of bismuth in biological samples using on-line flow-injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rivas, C ;
Rondon, C ;
Carrero, P ;
Gallignani, M .
TALANTA, 1999, 48 (04) :885-893
[5]  
CESSNER A, 2002, EUR J PHARM BIOPHARM, V54, P165
[6]   Determination of trace metals in saline water using flow injection on-line precipitation coupled with inductively coupled plasma mass spectrometry [J].
Chen, HH ;
Beauchemin, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1356-1363
[7]   Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisation [J].
Eroglu, AE ;
McLeod, CW ;
Leonard, KS ;
McCubbin, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1221-1233
[8]  
Fang Z., 1993, FLOW INJECTION SEPAR
[9]   FLOW-INJECTION ONLINE COPRECIPITATION PRECONCENTRATION FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
DONG, LP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :439-445
[10]   Bead injection with a simple flow-injection system: an economical alternative for trace analysis [J].
Hartwell, SK ;
Christian, GD ;
Grudpan, K .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (09) :619-623