Selective and specific detection of sulfate-reducing bacteria using potentiometric stripping analysis

被引:15
作者
Wan, Yi [2 ]
Zhang, Dun [1 ]
Hou, Baorong
机构
[1] Chinese Acad Sci, Inst Oceanol, Key Lab Corros Sci, Qingdao 266071, Shandong, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
基金
中国国家自然科学基金;
关键词
Potentiometric stripping analysis; Sulfate-reducing bacteria; Pathogenic bacteria detection; Sulfide; ELECTROCHEMICAL IMMUNOSENSOR; RAPID DETECTION; WATER SAMPLES; CADMIUM; COPPER; LEAD; METALLOIMMUNOASSAY; LABEL; QUANTIFICATION; IDENTIFICATION;
D O I
10.1016/j.talanta.2010.07.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, sensitive and reliable potentiometric stripping analysis (PSA) is described for the selective detection of the marine pathogenic sulfate-reducing bacterium (SRB). Desulforibrio caledoiensis. The chemical and electrochemical parameters that exert influence on the deposition and stripping of lead ion, such as deposition potential, deposition time and pH value were carefully studied. The concentration of SRB was determined in acetate buffer solution (pH 5.2) under the optimized condition (deposition potential of -1.3 V. deposition time of 250 s, ionic strength of 0.2 mol L-1 and oxidant mercury (II) concentration of 40 mg L-1). A linear relationship between the stripping response and the logarithm of the bacterial concentration was observed in the range of 2.3 x 10 to 2.3 x 10(7) cfu mL(-1). In addition, the potentiometric stripping technique gave a distinct response to the SRB, but had no obvious response to Escherichia coli. The measurement system has a potential for further applications and provides a facile and sample method for detection of pathogenic bacteria. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1608 / 1611
页数:4
相关论文
共 34 条
[1]   COUNTING OF SULPHATE-REDUCING BACTERIA IN MIXED BACTERIAL POPULATIONS [J].
ABDELMALEK, Y ;
RIZK, SG .
NATURE, 1958, 182 (4634) :538-538
[2]  
Chen Guo Nan, 1994, American Journal of Enology and Viticulture, V45, P305
[3]   Silver-enhanced colloidal gold metalloimmunoassay for Schistosoma japonicum antibody detection [J].
Chu, X ;
Xiang, ZF ;
Fu, X ;
Wang, SP ;
Shen, GL ;
Yu, RQ .
JOURNAL OF IMMUNOLOGICAL METHODS, 2005, 301 (1-2) :77-88
[4]   An electrochemical stripping metalloimmunoassay based on silver-enhanced gold nanoparticle label [J].
Chu, X ;
Fu, X ;
Chen, K ;
Shen, GL ;
Yu, RQ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1805-1812
[5]   Determination of total copper in white wine by stripping potentiometry utilising medium exchange [J].
Clark, AC ;
Scollary, GR .
ANALYTICA CHIMICA ACTA, 2000, 413 (1-2) :25-32
[6]   Environmental contamination from lead, copper and cadmium - Determination using the woodlouse as bioaccumulator and potentiometric stripping analysis for measurement [J].
Crowther, D ;
Rogerson, V ;
Cooke, M .
ANALYTICAL COMMUNICATIONS, 1996, 33 (03) :93-94
[7]   Supported liquid membrane coupled on-line to potentiometric stripping analysis at a mercury-coated reticulated vitreous carbon electrode for trace metal determinations in urine [J].
Djane, NK ;
Armalis, S ;
Ndung'u, K ;
Johansson, G ;
Mathiasson, L .
ANALYST, 1998, 123 (02) :393-396
[8]   Salmonella typhi determination using voltammetric amplification of nanoparticles: A highly sensitive strategy for metalloimmunoassay based on a copper-enhanced gold label [J].
Dungchai, Wijitar ;
Siangproh, Weena ;
Chaicumpa, Wanpen ;
Tongtawe, Pongsri ;
Chailapakul, Orawon .
TALANTA, 2008, 77 (02) :727-732
[9]   Sensitive cadmium potentiometric sensor based on 4-hydroxy salophen as a fast tool for water samples analysis [J].
Ensafi, Ali A. ;
Meghdadi, S. ;
Sedighi, S. .
DESALINATION, 2009, 242 (1-3) :336-345
[10]   Electrochemical biosensor array for the identification of microorganisms based on lectin-lipopolysaccharide recognition [J].
Ertl, P ;
Mikkelsen, SR .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4241-4248