Below-knee residual limb shape change measurement and visualization

被引:24
作者
Commean, PK
Brunsden, BS
Smith, KE
Vannier, MW
机构
[1] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
[2] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1998年 / 79卷 / 07期
关键词
D O I
10.1016/S0003-9993(98)90355-0
中图分类号
R49 [康复医学];
学科分类号
100215 [康复医学与理疗学];
摘要
Objective: The ability to measure and visualize shape change (deformation) of a residual limb within and between prostheses is an important step toward improved prosthetic fit assessment. The objective was to develop measurement and visualization methods for below-knee residual limb soft tissue shape change after donning and loading a prosthesis to detect small shape changes (30mm or less). Design: Spiral X-ray computed tomography imaging was utilized to acquire 3D volumetric data of the below-knee residual limb and prosthesis in situ from poor- and a good-fitting prostheses without and with a load. A new sum projection depth-shaded cylindrical mapping technique to measure and visualize small changes in shape was developed. From the volumetric data, the relative displacement of small lead markers placed on the residual limb's skin surface were measured using multiplanar reconstruction images and cylindrical maps. Displacement measurements averaging 15mm or less were obtained. Results: The precision and accuracy was 1mm and 2mm, respectively, when measuring the shape change or deformation of the skin surface from the sum projection cylindrical maps. The skin surface deformation was at least 7mm or greater when comparing marker locations between scans with the prostheses in situ, Conclusion: These new image-based measurement and visualization methods provide a feasible means for measuring and displaying lower extremity residual limb shape change within and between different prostheses with and without loading. (C) 1998 by the American Congress of Rehabilitation Medicine ann the American Academy of Physical Medicine and Rehabilitation.
引用
收藏
页码:772 / 782
页数:11
相关论文
共 28 条
[1]
[Anonymous], J PROSTHET ORTHOT
[2]
[Anonymous], 3 DIMENSIONAL BIOMED
[3]
BEDNARCZYK JH, 1992, ARCH PHYS MED REHAB, V73, P60
[4]
Precision of surface measurements for below-knee residua [J].
Commean, PK ;
Smith, KE ;
Cheverud, JM ;
Vannier, MW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (05) :477-486
[5]
Lower extremity residual limb slippage within the prosthesis [J].
Commean, PK ;
Smith, KE ;
Vannier, MW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (05) :476-485
[6]
Commean PK, 1996, J REHABIL RES DEV, V33, P267
[7]
COMMEAN PK, 1996, IMAGE PROCESSING, P494
[8]
COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[9]
FAULKNER V, 1988, ORTHOTICS PROSTHET, V41, P57
[10]
COMPUTER DESIGNED PROSTHETIC SOCKET FROM ANALYSIS OF COMPUTED-TOMOGRAPHY DATA [J].
FAULKNER, VW ;
WALSH, NE .
JOURNAL OF PROSTHETICS AND ORTHOTICS, 1989, 1 (03) :154-164