Analysis of gangliosides directly from thin-layer chromatography plates by infrared matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry with a glycerol matrix

被引:90
作者
Dreisewerd, K [1 ]
Müthing, J
Rohlfing, A
Meisen, I
Vukelic, Z
Peter-Katalinic, J
Hillenkamp, F
Berkenkamp, S
机构
[1] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
[2] Univ Zagreb, Fac Med, Dept Chem & Biochem, Zagreb 10000, Croatia
[3] Sequenom GmbH, D-22761 Hamburg, Germany
关键词
D O I
10.1021/ac048373w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method is presented for direct coupling of high-performance thin-layer chromatography (HPTLC) with matrix-assisted laser desorption/ionization mass spectrometty (MALDI-MS) for the analysis of biomolecules. A first key feature is the use of a liquid matrix (glycerol), which provides a homogeneous wetting of the silica gel and a simple and fast MALDI preparation protocol. A second is the use of an Er:YAG infrared laser, which ablates layers of similar to 10-mu m thickness of analyte-loaded silica gel and provides a soft desorption/ionization of even very labile analyte molecules. The orthogonal time-of-flight mass spectrometer employed in this study, finally provides a high accuracy of the mass determination, which is independent of any irregularity of the silica gel surface. The analytical potential of the method is demonstrated by the compositional mapping of a native GM3 (II3-alpha-Neu5Ac-LacCer) ganglioside mixture from cultured Chinese hamster ovary cells. The analysis is characterized by a high relative sensitivity, allowing the simultaneous detection of various major and minor GM3 species directly from individual HPTLC analyte bands. The lateral resolution of the direct HPTLC-MALDI-MS analysis is defined by the laser focus diameter of currently similar to 200 mu m. This allows one to determine mobility profiles of individual species with a higher resolution than by reading off the chromatogram by optical absorption. The fluorescent dye primuline was, furthermore, successfully tested as a nondestructive, MALDI-compatible staining agent.
引用
收藏
页码:4098 / 4107
页数:10
相关论文
共 43 条
[21]   Discrimination of neolacto-series gangliosides with α2-3- and α2-6-linked N-acetylneuraminic acid by nanoelectrospray ionization low-energy collision-induced dissociation tandem quadrupole TOF MS [J].
Meisen, I ;
Peter-Katalinic, J ;
Müthing, J .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5719-5725
[22]   Mechanisms of energy deposition in infrared matrix-assisted laser desorption/ionization mass spectrometry [J].
Menzel, C ;
Dreisewerd, K ;
Berkenkamp, S ;
Hillenkamp, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 207 (1-2) :73-96
[23]  
Metelmann W, 2000, RAPID COMMUN MASS SP, V14, P543, DOI 10.1002/(SICI)1097-0231(20000415)14:7<543::AID-RCM908>3.0.CO
[24]  
2-J
[25]  
Mowthorpe S, 1999, RAPID COMMUN MASS SP, V13, P264, DOI 10.1002/(SICI)1097-0231(19990228)13:4<264::AID-RCM460>3.0.CO
[26]  
2-M
[27]   High-resolution thin-layer chromatography of gangliosides [J].
Muthing, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :3-25
[28]   A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces [J].
O'Connor, PB ;
Budnik, BA ;
Ivleva, VB ;
Kaur, P ;
Moyer, SC ;
Pittman, JL ;
Costello, CE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (01) :128-132
[29]   High pressure matrix-assisted laser desorption/ionization Fourier transform mass spectrometry for minimization of ganglioside fragmentation [J].
O'Connor, PB ;
Mirgorodskaya, E ;
Costello, CE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (04) :402-407
[30]   DESORPTION MASS-SPECTROMETRY OF GLYCOSPHINGOLIPIDS [J].
PETERKATALINIC, J ;
EGGE, H .
METHODS IN ENZYMOLOGY, 1990, 193 :713-733