Laser ablation inductively coupled plasma mass spectrometry measurement of isotope ratios in depleted uranium contaminated soils

被引:14
作者
Seltzer, MD [1 ]
机构
[1] USN, Air Warfare Ctr, Weap Div, China Lake, CA 93555 USA
关键词
laser ablation; inductively coupled plasma mass spectrometry; ICP-MS; isotope ratios; depleted uranium;
D O I
10.1366/00037020360696053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Laser ablation of pressed soil pellets was examined as a means of direct sample introduction to enable inductively coupled plasma mass spectrometry (ICP-MS) screening of soils for residual depleted uranium (DU) contamination. Differentiation between depleted uranium, an anthropogenic contaminant, and naturally occurring uranium was accomplished on the basis of measured (UPU)-U-235-U-238 isotope ratios. The amount of sample preparation required for laser ablation is considerably less than that typically required for aqueous sample introduction. The amount of hazardous laboratory waste generated is diminished accordingly. During the present investigation, U-235/U-238 isotope ratios measured for field samples were in good agreement with those derived from gamma spectrometry measurements. However, substantial compensation was required to mitigate the effects of impaired pulse counting attributed to sample inhomogeneity and sporadic introduction of uranium analyte into the plasma.
引用
收藏
页码:1173 / 1177
页数:5
相关论文
共 36 条
  • [1] Implementation of ICP-MS protocols for uranium urinary measurements in worker monitoring
    Baglan, N
    Cossonnet, C
    Trompier, F
    Ritt, J
    Bérard, P
    [J]. HEALTH PHYSICS, 1999, 77 (04): : 455 - 461
  • [2] Analysis of soil and sediment samples by laser ablation inductively coupled plasma mass spectrometry
    Baker, SA
    Bi, M
    Aucelio, RQ
    Smith, BW
    Winefordner, JD
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (01) : 19 - 26
  • [3] Inductively coupled plasma mass spectrometry
    Beauchemin, D
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2873 - 2893
  • [4] Laser ablation inductively coupled plasma mass spectrometry for the trace, ultratrace and isotope analysis of long-lived radionuclides in solid samples
    Becker, JS
    Pickhardt, C
    Dietze, HJ
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 202 (1-3) : 283 - 297
  • [5] Ultratrace and isotope analysis of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using a direct injection high efficiency nebulizer
    Becker, JS
    Dietze, HJ
    McLean, JA
    Montaser, A
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3077 - 3084
  • [6] Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios
    Begley, IS
    Sharp, BL
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 395 - 402
  • [7] Laser ablation inductively coupled plasma mass spectrometry of pressed pellet surrogates for Pu materials disposition
    Borisov, OV
    Bannochie, CJ
    Russo, RE
    [J]. APPLIED SPECTROSCOPY, 2001, 55 (10) : 1304 - 1311
  • [8] Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples
    Boulyga, SF
    Becker, JS
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1143 - 1147
  • [9] Determination of 236U/238U isotope ratio in contaminated environmental samples using different ICP-MS instruments
    Boulyga, SF
    Matusevich, JL
    Mironov, VP
    Kudrjashov, VP
    Halicz, L
    Segal, I
    McLean, JA
    Montaser, A
    Becker, JS
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 958 - 964
  • [10] Optimisation and application of ICP-MS and alpha-spectrometry for determination of isotopic ratios of depleted uranium and plutonium in samples collected in Kosovo
    Boulyga, SF
    Testa, C
    Desideri, D
    Becker, JS
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (11) : 1283 - 1289