A Microarray Biosensor for Multiplexed Detection of Microbes Using Grating-Coupled Surface Plasmon Resonance Imaging

被引:38
作者
Marusov, Gregory [1 ]
Sweatt, Andrew [1 ]
Pietrosimone, Kathryn [1 ]
Benson, David [1 ]
Geary, Steven J. [2 ,4 ]
Silbart, Lawrence K. [3 ,4 ]
Challa, Sreerupa [3 ,4 ]
Lagoy, Jacqueline [1 ]
Lawrence, David A. [5 ]
Lynes, Michael A. [1 ,4 ]
机构
[1] Univ Connecticut, Dept Mol & Cell Biol, Storrs, CT 06269 USA
[2] Univ Connecticut, Dept Pathobiol, Storrs, CT 06269 USA
[3] Univ Connecticut, Dept Allied Hlth Sci, Storrs, CT 06269 USA
[4] Univ Connecticut, Ctr Excellence Vaccine Res, Storrs, CT 06269 USA
[5] New York Dept Hlth, Wadsworth Ctr, Albany, NY 12208 USA
关键词
ESCHERICHIA-COLI O157-H7; PROPIDIUM MONOAZIDE; QUANTITATIVE PCR; BIOMOLECULAR INTERACTIONS; STAPHYLOCOCCAL-ENTEROTOXIN; LISTERIA-MONOCYTOGENES; BACTERIAL INDICATORS; ENTERIC VIRUSES; SPR BIOSENSOR; WATER SAMPLES;
D O I
10.1021/es201239f
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Grating-coupled surface plasmon resonance imaging (GCSPRI) utilizes an optical diffraction grating embossed on a gold-coated sensor chip to couple collimated incident light into surface plasmons. The angle at which this coupling occurs is sensitive to the capture of analyte at the chip surface. This approach permits the use of disposable biosensor chips that can be mass-produced at low cost and spotted in microarray format to greatly increase multiplexing capabilities. The current GCSPRI instrument has the capacity to simultaneously measure binding at over 1000 unique, discrete regions of interest (ROIs) by utilizing a compact microarray of antibodies or other specific capture molecules immobilized on the sensor chip. In this report, we describe the use of GCSPRI to directly detect multiple analytes over a large dynamic range, including soluble protein toxins, bacterial cells, and viruses, in near real-time. GCSPRI was used to detect a variety of agents that would be useful for diagnostic and environmental sensing purposes, including macromolecular antigens, a nontoxic form of Pseudomonas aeruginosa exotoxin A (ntPE), Bacillus globigii, Mycoplasma hyopneumoniae, Listeria monocytogenes, Escherichia coli, and M13 bacteriophage. These studies indicate that GCSPRI can be used to simultaneously assess the presence of toxins and pathogens, as well as quantify specific antibodies to environmental agents, in a rapid, label-free, and highly multiplexed assay requiring nanoliter amounts of capture reagents.
引用
收藏
页码:348 / 359
页数:12
相关论文
共 81 条
[71]   Grating-coupled surface plasmon resonance: A cell and protein microarray platform [J].
Unfricht, DW ;
Colpitts, SL ;
Fernandez, SM ;
Lynes, MA .
PROTEOMICS, 2005, 5 (17) :4432-4442
[72]   Ultrasensitive quartz crystal microbalance sensors for detection of M13-Phages in liquids [J].
Uttenthaler, E ;
Schräml, M ;
Mandel, J ;
Drost, S .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :735-743
[73]   Surface plasmon resonance biosensor for direct detection of antibody against Epstein-Barr virus [J].
Vaisocherova, Hana ;
Mrkvova, Katerina ;
Piliarik, Marek ;
Jinoch, Pavel ;
Steinbachova, Marie ;
Homola, Jiri .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :1020-1026
[74]   Quantifying fungal viability in air and water samples using quantitative PCR after treatment with propidium monoazide (PMA) [J].
Vesper, Stephen ;
McKinstry, Craig ;
Hartmann, Chris ;
Neace, Michelle ;
Yoder, Stephanie ;
Vesper, Alex .
JOURNAL OF MICROBIOLOGICAL METHODS, 2008, 72 (02) :180-184
[75]   Micro- and nanomechanical sensors for environmental, chemical, and biological detection [J].
Waggoner, Philip S. ;
Craighead, Harold G. .
LAB ON A CHIP, 2007, 7 (10) :1238-1255
[76]   Determination of the Effects of Medium Composition on the Monochloramine Disinfection Kinetics of Nitrosomonas europaea by the Propidium Monoazide Quantitative PCR and Live/Dead BacLight Methods [J].
Wahman, David G. ;
Schrantz, Karen A. ;
Pressman, Jonathan G. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2010, 76 (24) :8277-8280
[77]   Quantitation of bacteria in blood of typhoid fever patients and relationship between counts and clinical features, transmissibility, and antibiotic resistance [J].
Wain, J ;
Diep, TS ;
Ho, VA ;
Walsh, AM ;
Hoa, NTT ;
Parry, CM ;
White, NJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (06) :1683-1687
[78]   Direct detection of E-Coli O157:H7 in selected food systems by a surface plasmon resonance biosensor [J].
Waswa, John ;
Irudayaraj, Joseph ;
DebRoy, Chitrita .
LWT-FOOD SCIENCE AND TECHNOLOGY, 2007, 40 (02) :187-192
[79]   PCR-based diagnostics for infectious diseases: uses, limitations, and future applications in acute-care settings [J].
Yang, S ;
Rothman, RE .
LANCET INFECTIOUS DISEASES, 2004, 4 (06) :337-348
[80]   Direct pathogen detection from swab samples using a new high-throughput sequencing technology [J].
Yongfeng, H. ;
Fan, Y. ;
Jie, D. ;
Jian, Y. ;
Ting, Z. ;
Lilian, S. ;
Jin, Q. .
CLINICAL MICROBIOLOGY AND INFECTION, 2011, 17 (02) :241-244