The commercially available dye, NanoOrange, has been investigated asa potential tool for clinical diagnostics due to its low cost, ease of use, and ability to detect nanomolar concentrations of protein. Virtually non-fluorescent in dilute aqueous solutions, NanoOrange fluorescence is enhanced by at least an order of magnitude upon non-covalent interaction with proteins. These features, coupled with the requirement for high throughput assays in the clinical laboratory has prompted the development of two orthogonal NanoOrange approaches. Human serum albumin (HSA) was used as a model protein for the development of both 96-well microplate and capillary electrophoresis laser-induced fluorescence (CE-LIF) assay formats. Dye performance in five commonly used buffers of various concentrations and pH indicated considerable flexibility in assay buffer selection, with optimal performance at pH 9.0. A salt concentration study indicated that increasing NaCl concentration generally decreases fluorescence emission and can be minimized by pre-diluting biological samples to a final salt concentration of 20-80 mM. Titration of protein with NanoOrange resulted in optimal HSA-NanoOrange complex formation utilizing 1x and 2x NanoOrange in the 96-well microplate and CE-LIF approaches, respectively. A NanoOrange binding model based on rapid signal enhancement and zero order fluorescence emission kinetics is proposed. The utilization of NanoOrange in CE-LIF based human serum analysis results in a signal-to-background ratio improvement of up to two orders of magnitude. (C) 2001 Elsevier Science B.V. Ail rights reserved.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 27 条
[1]   MONITORING OF A CONJUGATION REACTION BETWEEN FLUORESCEIN ISOTHIOCYANATE AND MYOGLOBIN BY CAPILLARY ZONE ELECTROPHORESIS [J].
BANKS, PR ;
PAQUETTE, DM .
JOURNAL OF CHROMATOGRAPHY A, 1995, 693 (01) :145-154
[2]  
Bossuyt X, 1998, CLIN CHEM, V44, P749
[3]   Analysis of urinary drugs of abuse by a multianalyte capillary electrophoretic immunoassay [J].
Caslavska, J ;
Allemann, D ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 1999, 838 (1-2) :197-211
[4]   Biosensor analysis of the interaction between immobilized human serum albumin and drug compounds for prediction of human serum albumin binding levels [J].
Frostell-Karlsson, Å ;
Remaeus, A ;
Roos, H ;
Andersson, K ;
Borg, P ;
Hämäläinen, M ;
Karlsson, R .
JOURNAL OF MEDICINAL CHEMISTRY, 2000, 43 (10) :1986-1992
[5]   Rapid simultaneous determination of glucagon and insulin by capillary electrophoresis immunoassays [J].
German, I ;
Kennedy, RT .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02) :353-362
[6]   Subnanomolar detection limit for sodium dodecyl sulfate capillary gel electrophoresis using a fluorogenic, noncovalent dye [J].
Harvey, MD ;
Bandilla, D ;
Banks, PR .
ELECTROPHORESIS, 1998, 19 (12) :2169-2174
[7]  
Haugland R.P., 1996, Handbook of Fluorescent Probes and Research Chemicals
[8]   Capillary electrophoresis sodium dodecyl sulfate nongel sieving analysis of a therapeutic recombinant monoclonal antibody: A biotechnology perspective [J].
Hunt, G ;
Nashabeh, W .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2390-2397
[9]   Arterial hypertension, microalbuminuria, and risk of ischemic heart disease [J].
Jensen, JS ;
Feldt-Rasmussen, B ;
Strandgaard, S ;
Schroll, M ;
Borch-Johnsen, K .
HYPERTENSION, 2000, 35 (04) :898-903
[10]  
Kelly MT, 2000, ELECTROPHORESIS, V21, P699