The GlucoWatch® biographer:: a frequent, automatic and noninvasive glucose monitor

被引:90
作者
Tierney, MJ [1 ]
Tamada, JA [1 ]
Potts, RO [1 ]
Eastman, RC [1 ]
Pitzer, K [1 ]
Ackerman, NR [1 ]
Fermi, SJ [1 ]
机构
[1] Cygnus Inc, Redwood City, CA 94063 USA
关键词
biosensing techniques; blood glucose self-monitoring; diabetes mellitus; hypoglycaemia; noninvasive glucose monitoring;
D O I
10.3109/07853890009002034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The GlucoWatch(R) (Cygnus, Inc, Redwood City, CA, USA) biographer provides automatic, frequent and noninvasive blood glucose measurements for up to 12 h. The device extracts glucose through intact skin where it is measured by an amperometric biosensor. Clinical trials in a variety of environments have shown that the biographer provides accurate and precise glucose measurements when compared with serial fingerstick blood glucose measurements. Mean difference between these measurements was 0.26 mmol/L in the home environment (r = 0.80). Over 94% of biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low glucose levels. Biographer precision, as measured by coefficient of variation (CV)%, is approximately 10%. The low glucose alert function of the biographer was able to detect up to 75% of hypoglycaemic episodes with a low false alert level. Skin irritation, characterized by erythema and oedema was either nonexistent or mild in over 87% of subjects and resolved in virtually all subjects without treatment in several days. The GlucoWatch(R) biographer has been shown to be a safe and effective method to track glucose level trends and patterns, which should enable improved glycaemic control for many patients.
引用
收藏
页码:632 / 641
页数:10
相关论文
共 28 条
[1]  
Amer Diabet Assoc, 2000, DIABETES CARE, V23, pS32
[2]   Phantom glucose calibration models from simulated noninvasive human near-infrared spectra [J].
Arnold, MA ;
Burmeister, JJ ;
Small, GW .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1773-1781
[3]  
BERMEISTER JJ, 2000, DIABETES TECHNOL THE, V2, P5
[4]   Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions [J].
Bolinder, J ;
HagstromToft, E ;
Ungerstedt, U ;
Arner, P .
DIABETES CARE, 1997, 20 (01) :64-70
[5]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[6]  
Edelman S, 2000, DIABETES, V49, pA104
[7]   Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia [J].
Gabriely, I ;
Wozniak, R ;
Mevorach, M ;
Kaplan, J ;
Aharon, Y ;
Shamoon, H .
DIABETES CARE, 1999, 22 (12) :2026-2032
[8]   Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes [J].
Garg, SK ;
Potts, RO ;
Ackerman, NR ;
Fermi, SJ ;
Tamada, JA ;
Chase, HP .
DIABETES CARE, 1999, 22 (10) :1708-1714
[9]  
GINSBERG BH, 1992, CLIN CHEM, V38, P1596
[10]   NONINVASIVE SAMPLING OF BIOLOGICAL-FLUIDS BY IONTOPHORESIS [J].
GLIKFELD, P ;
HINZ, RS ;
GUY, RH .
PHARMACEUTICAL RESEARCH, 1989, 6 (11) :988-990