Cantilever tip probe arrays for simultaneous SECM and AFM analysis

被引:57
作者
Fasching, RJ [1 ]
Tao, Y [1 ]
Prinz, FB [1 ]
机构
[1] Stanford Univ, Rapid Prototyping Lab, Stanford, CA 94305 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2005年 / 108卷 / 1-2期
关键词
SECM; AFM; FIB; nano electrodes; tip probe array;
D O I
10.1016/j.snb.2004.10.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A cantilever transducer system with platinum tip electrodes in sub-micron regime has been fabricated for simultaneous Scanning Electrochemical Microscopy (SECM) and Atomic Force Microscopy (AFM) analysis. Sharpened High Aspect Ratio Silicon (HARS) tips are shaped combining isotropic and anisotropic deep-reactive etch processes and form the body of the transducer. Deposition of a silicon nitride followed by a back etch step allows embedding these silicon tips in a silicon nitride layer so that they protrude through the nitride. This way, embedded silicon tips with a diameter smaller than 600 nm, a radius smaller than 50 nm, and an aspect ratio higher than 20 can be achieved. Subsequently, a platinum layer and an insulator layer are deposited on these tip structures. Introducing a metal masking technology utilizing Focused Ion Beam (FIB) technology, a precise exposure of the buried metal layer can be achieved to form ultra micro-electrodes on top of the tip. Finally, cantilever structures are shaped and released by etching the silicon substrate from the backside. Electrochemical and mechanical characterization show full functionality of the transducer system. Due to the high aspect ratio topography of the tip structure and low spring constant of silicon nitride cantilevers, these probes are particularly suited for high resolution SECM and AFM analysis. Furthermore, this technology allows a production of both linear probe arrays and two-dimensional probe arrays. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:964 / 972
页数:9
相关论文
共 20 条
  • [1] MICROFABRICATION OF CANTILEVER STYLI FOR THE ATOMIC FORCE MICROSCOPE
    ALBRECHT, TR
    AKAMINE, S
    CARVER, TE
    QUATE, CF
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (04): : 3386 - 3396
  • [2] Bard A.J., 1994, ELECTROANAL CHEM, V18, A., P243
  • [3] Bard A.J., 2001, Scanning Electrochemical Microscopy
  • [4] SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES
    BARD, AJ
    FAN, FRF
    KWAK, J
    LEV, O
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (02) : 132 - 138
  • [5] CHEMICAL IMAGING OF SURFACES WITH THE SCANNING ELECTROCHEMICAL MICROSCOPE
    BARD, AJ
    FAN, FRF
    PIERCE, DT
    UNWIN, PR
    WIPF, DO
    ZHOU, FM
    [J]. SCIENCE, 1991, 254 (5028) : 68 - 74
  • [6] AFM probes with directly fabricated tips
    Boisen, A
    Hansen, O
    Bouwstra, S
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1996, 6 (01) : 58 - 62
  • [7] Bonnell D., 2000, Scanning probe microscopy and spectroscopy
  • [8] Scanning electrochemical microscopy with shear force feedback -: Investigation of the lateral resolution of different experimental configurations
    Büchler, M
    Kelley, SC
    Smyrl, WH
    [J]. ELECTROCHEMICAL AND SOLID STATE LETTERS, 2000, 3 (01) : 35 - 38
  • [9] FAN FRF, 2001, SCANNING ELECTROCHEM
  • [10] A pencil probe system for electrochemical analysis and modification in nanometer dimensions
    Fasching, RJ
    Tao, Y
    Hammerick, K
    Prinz, FB
    [J]. SMART SENSORS, ACTUATORS, AND MEMS, PTS 1 AND 2, 2003, 5116 : 128 - 135