Lymph node metastases: Safety and effectiveness of MR imaging with ultrasmall superparamagnetic iron oxide particles - Initial clinical experience

被引:204
作者
Bellin, MF
Roy, C
Kinkel, K
Thoumas, D
Zaim, S
Vanel, D
Tuchmann, C
Richard, F
Jacqmin, D
Delcourt, A
Challier, E
Lebret, T
Cluzel, P
机构
[1] Hop La Pitie Salpetriere, Dept Radiol, F-75651 Paris 13, France
[2] Hop La Pitie Salpetriere, Dept Urol, F-75651 Paris 13, France
[3] Hop La Pitie Salpetriere, Dept Pathol, F-75651 Paris 13, France
[4] CHU Strasbourg, Dept Radiol, F-67000 Strasbourg, France
[5] CHU Strasbourg, Dept Urol, F-67000 Strasbourg, France
[6] Inst Gustave Roussy, Dept Radiol, Villejuif, France
[7] CHU Rouen, Dept Radiol, Rouen, France
关键词
genitourinary system; neoplasms; lymphatic system; MR; Lymphatic system; magnetic resonance (MR); contrast enhancement; pelvic organs;
D O I
10.1148/radiology.207.3.9609907
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To evaluate the clinical and biologic safety of ultrasmall superparamagnetic iron oxide particles (AMI-227) as a contrast agent for magnetic resonance (MR) lymphography and to assess their efficacy for the differentiation of metastatic and benign nodes in patients with urologic and pelvic cancer. MATERIALS AND METHODS: Thirty adults suspected of having lymph node metastases underwent MR imaging before and 22-26 hours after intravenous infusion of AMI-227 (1.7 mg Fe/kg). Sixty histopathologically proved lymph nodes were analyzed on MR images, and 29 of these nodes were also analyzed quantitatively. RESULTS: AMI-227 was well tolerated with no major side effects. It allowed the detection of 10 additional nodes relative to those detected at MR imaging without AMI-227. None of the 27 metastatic nodes showed a decrease in signal intensity (SI) on AMI-227-enhanced images; nine of 27 metastatic nodes showed an increase in SI on T1-weighted images, probably resulting from altered capillary permeability in the tumor. A visually perceptible reduction in SI, indicating active AMI-227 uptake, was observed on postcontrast T2- and T2*-weighted images in 16 of 21 benign nodes. The SI ratio of benign nodes was lower than that of metastatic nodes on T2- and T2*-weighted images. The sensitivity of AMI-227-enhanced MR lymphography was 100%, and the specificity was 80%. CONCLUSION: AMI-227 is safe and may facilitate the differentiation of metastatic and benign nodes in patients with urologic and pelvic cancers.
引用
收藏
页码:799 / 808
页数:10
相关论文
共 41 条
[1]
Iron oxide-enhanced MR lymphography: The evaluation of cervical lymph node metastases in head and neck cancer [J].
Anzai, Y ;
Prince, MR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :75-81
[2]
INITIAL CLINICAL-EXPERIENCE WITH DEXTRAN-COATED SUPERPARAMAGNETIC IRON-OXIDE FOR DETECTION OF LYMPH-NODE METASTASES IN PATIENTS WITH HEAD AND NECK-CANCER [J].
ANZAI, Y ;
BLACKWELL, KE ;
HIRSCHOWITZ, SL ;
ROGERS, JW ;
SATO, Y ;
YUH, WTC ;
RUNGE, VM ;
MORRIS, MR ;
MCLACHLAN, SJ ;
LUFKIN, RB .
RADIOLOGY, 1994, 192 (03) :709-715
[3]
ANZAI Y, 1994, AM J NEURORADIOL, V15, P87
[4]
LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[5]
PELVIC CANCERS - STAGING OF 139 CASES WITH LYMPHOGRAPHY AND FINE-NEEDLE ASPIRATION BIOPSY [J].
CHAGNON, S ;
COCHANDPRIOLLET, B ;
GZAEIL, M ;
JACQUENOD, P ;
ROGER, B ;
BOCCONGIBOD, L ;
BLERY, M .
RADIOLOGY, 1989, 173 (01) :103-106
[6]
SUPERPARAMAGNETIC IRON-OXIDES AS POSITIVE MR CONTRAST AGENTS - INVITRO AND INVIVO EVIDENCE [J].
CHAMBON, C ;
CLEMENT, O ;
LEBLANCHE, A ;
SCHOUMANCLAEYS, E ;
FRIJA, G .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :509-519
[7]
DAVIS GL, 1995, CANCER, V76, P661, DOI 10.1002/1097-0142(19950815)76:4<661::AID-CNCR2820760419>3.0.CO
[8]
2-S
[9]
MAGNETIC-RESONANCE IMAGING OF THE LYMPH-NODES - COMPARISON WITH CT [J].
DOOMS, GC ;
HRICAK, H ;
CROOKS, LE ;
HIGGINS, CB .
RADIOLOGY, 1984, 153 (03) :719-728
[10]
CHARACTERIZATION OF LYMPHADENOPATHY BY MAGNETIC-RESONANCE RELAXATION-TIMES - PRELIMINARY-RESULTS [J].
DOOMS, GC ;
HRICAK, H ;
MOSELEY, ME ;
BOTTLES, K ;
FISHER, M ;
HIGGINS, CB .
RADIOLOGY, 1985, 155 (03) :691-697