A review of the recent achievements in capacitively coupled contactless conductivity detection

被引:221
作者
Kuban, Pavel [2 ]
Hauser, Peter C. [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
[2] Acad Sci Czech Republ, Inst Analyt Chem, Brno 60200, Czech Republic
关键词
capillary electrophoresis; contactless conductivity detection; flow injection analysis; liquid chromatography; microchip capillary electrophoresis; review;
D O I
10.1016/j.aca.2007.11.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capacitively coupled contactless conductivity detection (CID) in the axial electrode configuration was introduced in 1998 as a quantification method for capillary electrophoresis. Its universality allows the detection of small inorganic ions as well as organic and biochemical species. Due to its robustness, minimal maintenance demands and low cost the popularity of this detector has been steadily growing. Applications have recently also been extended to other analytical methods such as ion chromatography, high-performance liquid chromatography and flow-injection analysis. (CD)-D-4 has also found use for detection on electrophoresis based lab-on-chip devices. Theoretical aspects of (CD)-D-4 in both the capillary and microchip electrophoresis format have been comprehensively investigated. Commercial devices are now available and the method can be considered a mature detection technique. In this article, the achievements in CID for the time period between September 2004 and August 2007 are reviewed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 29
页数:15
相关论文
共 110 条
[71]   Capillary electrophoresis analysis of fosfomycin in biological fluids for clinical pharmacokinetic studies [J].
Petsch, M ;
Mayer-Helm, BX ;
Sauermann, R ;
Joukhadar, C ;
Kenndler, E .
ELECTROPHORESIS, 2004, 25 (14) :2292-2298
[72]   Formamide as solvent for capillary zone electrophoresis [J].
Porras, SP ;
Kenndler, E .
ELECTROPHORESIS, 2004, 25 (17) :2946-2958
[73]   Poly(methyl methacrylate) CE microchips replicated from poly(dimethylsiloxane) templates for the determination of cations [J].
Qu, Song ;
Chen, Xiaohong ;
Chen, Di ;
Yang, Penyuan ;
Chen, Gang .
ELECTROPHORESIS, 2006, 27 (24) :4910-4918
[74]   Fast electrophoresis in conventional capillaries by employing a rapid injection device and contactless conductivity detection [J].
Rainelli, A ;
Hauser, PC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (03) :789-794
[75]  
Richter EM, 2005, J BRAZIL CHEM SOC, V16, P1134, DOI 10.1590/S0103-50532005000700008
[76]   Monitoring the electroosmotic flow in capillary electrophoresis using contactless conductivity detection and thermal marks [J].
Saito, Renata Mayumi ;
Neves, Carlos Antonio ;
Lopes, Fernando Silva ;
Blanes, Lucas ;
Alves Brito-Neto, Jose Geraldo ;
do Lago, Claudimir Lucio .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :215-223
[77]   Determination of proteinogenic amino acids in human plasma by capillary electrophoresis with contactless conductivity detection [J].
Samcová, E ;
Tuma, P .
ELECTROANALYSIS, 2006, 18 (02) :152-157
[78]   Determination of purity degree and counter-ion content in lecirelin by capillary zone electrophoresis and capillary isotachophoresis [J].
Sazelova, Petra ;
Kasicka, Vaclav ;
Solinova, Veronika ;
Koval, Dusan .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 841 (1-2) :145-151
[79]   Recent applications of conductivity detection in capillary and chip electrophoresis [J].
Solinova, Veronika ;
Kasicka, Vasclav .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (12) :1743-1762
[80]   Nitromethane as solvent in capillary electrophoresis [J].
Subirats, X ;
Porras, SP ;
Rosés, M ;
Kenndler, E .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :246-253