A review of the recent achievements in capacitively coupled contactless conductivity detection

被引:221
作者
Kuban, Pavel [2 ]
Hauser, Peter C. [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
[2] Acad Sci Czech Republ, Inst Analyt Chem, Brno 60200, Czech Republic
关键词
capillary electrophoresis; contactless conductivity detection; flow injection analysis; liquid chromatography; microchip capillary electrophoresis; review;
D O I
10.1016/j.aca.2007.11.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capacitively coupled contactless conductivity detection (CID) in the axial electrode configuration was introduced in 1998 as a quantification method for capillary electrophoresis. Its universality allows the detection of small inorganic ions as well as organic and biochemical species. Due to its robustness, minimal maintenance demands and low cost the popularity of this detector has been steadily growing. Applications have recently also been extended to other analytical methods such as ion chromatography, high-performance liquid chromatography and flow-injection analysis. (CD)-D-4 has also found use for detection on electrophoresis based lab-on-chip devices. Theoretical aspects of (CD)-D-4 in both the capillary and microchip electrophoresis format have been comprehensively investigated. Commercial devices are now available and the method can be considered a mature detection technique. In this article, the achievements in CID for the time period between September 2004 and August 2007 are reviewed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 29
页数:15
相关论文
共 110 条
[91]   A sample introduction method based on negative pressure in flow injection-capillary electrophoresis system and its application to the alkaline-earth metal cation separation [J].
Wang, JW ;
Cai, PX ;
Mo, JY ;
Chen, ZG .
ANALYTICAL LETTERS, 2005, 38 (05) :857-867
[92]   Running buffers for determination of chromium(VI)/(III), cobalt(II) and zinc(II) in complex matrices by capillary electrophoresis with contactless conductivity detection [J].
Wang, Li-Shi ;
Zhang, Shui-Feng ;
Dang, Zhi ;
Liu, Xiao-Xiao ;
Huang, Xin-Jian ;
Xiao, Ming-Wei ;
Chen, Zuan-Guang .
TALANTA, 2007, 72 (04) :1342-1347
[93]   Miniaturized capillary electrophoresis system with contactless conductivity detection and flow injection sample introduction [J].
Wang, LX ;
Fu, CG .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2004, 32 (03) :303-309
[94]   Rapid electrophoretic separations in short capillaries using contactless conductivity detection and a sequential injection analysis manifold for hydrodynamic sample loading [J].
Wuersig, Andreas ;
Kuban, Pavel ;
Khaloo, Shokooh S. ;
Hauser, Peter C. .
ANALYST, 2006, 131 (08) :944-949
[95]   Simultaneous determination of low-molecular-weight organic acids and chlorinated acid herbicides in environmental water by a portable CE system with contactless conductivity detection [J].
Xu, Yan ;
Wang, Weilong ;
Li, Sam Fong Yau .
ELECTROPHORESIS, 2007, 28 (10) :1530-1539
[96]   Carbon nanotube-enhanced separation of DNA fragments by a portable capillary electrophoresis system with contactless conductivity detection [J].
Xu, Yan ;
Li, Sam Fong Yau .
ELECTROPHORESIS, 2006, 27 (20) :4025-4028
[97]   Construction and analytical application of an on-column photo reactor for improved detection of iron-species as plant metabolites in capillary flow injection and capillary electrophoresis [J].
Xuan, Yue ;
Weber, Guenther ;
Manz, Andreas .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (02) :212-218
[98]  
Yang BC, 2005, CHINESE J ANAL CHEM, V33, P740
[99]   Tailoring elution of tetraalkylammonium ions. Ideal electrostatic selectivity elution order on a polymeric ion exchanger [J].
Yang, Bingcheng ;
Takeuchi, Masaki ;
Dasgupta, Purnendu K. ;
Umemura, Tomonari ;
Ueki, Yuji ;
Tsunoda, Kin-Ichi .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :769-772
[100]   Latex-coated polymeric monolithic ion-exchange stationary phases. 2. Micro-ion chromatography [J].
Zakaria, P ;
Hutchinson, JP ;
Avdalovic, N ;
Liu, Y ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :417-423