Rapid electrophoretic separations in short capillaries using contactless conductivity detection and a sequential injection analysis manifold for hydrodynamic sample loading

被引:36
作者
Wuersig, Andreas
Kuban, Pavel
Khaloo, Shokooh S.
Hauser, Peter C.
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
[2] Isfahan Univ Technol, Coll Chem, Esfahan 84156, Iran
关键词
D O I
10.1039/b606761a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential injection-capillary electrophoresis (SI-CE) system for the fast and automated quantitative analysis of anions and cations is described. Because of the low sample load in capillary electrophoresis a split injection approach had to be used to achieve reliable hydrodynamic injection. The use of a capillary of 8 cm effective length allowed for the separation of five inorganic cations within 11 s. One common electrolyte solution containing 12 mM L-histidine and 2 mM 18-crown-6 whose pH value was adjusted to 4.0 with 10% v/v acetic acid was used for anions and cations, thus the analysis of both groups of analytes could be carried out in rapid sequence simply by switching the polarity of the high voltage supply. The system also allows automated flushing of the capillary. Detection limits between about 2 and 5 mu mol l(-1) could be achieved with the contactless conductivity detector employed.
引用
收藏
页码:944 / 949
页数:6
相关论文
共 28 条
[1]  
Baltussen E, 2002, ELECTROPHORESIS, V23, P2888, DOI 10.1002/1522-2683(200209)23:17<2888::AID-ELPS2888>3.0.CO
[2]  
2-4
[3]   Understanding capacitively coupled contactless conductivity detection in capillary and microchip electrophoresis. Part 1. Fundamentals [J].
Brito-Neto, JGA ;
da Silva, JAF ;
Blanes, L ;
do Lago, CL .
ELECTROANALYSIS, 2005, 17 (13) :1198-1206
[4]   Understanding capacitively coupled contactless conductivity detection in capillary and microchip electrophoresis. Part 2. Peak shape, stray capacitance, noise, and actual electronics [J].
Brito-Neto, JGA ;
da Silva, JAF ;
Blanes, L ;
do Lago, CL .
ELECTROANALYSIS, 2005, 17 (13) :1207-1214
[5]   The combination of flow injection with electrophoresis using capillaries and chips [J].
Chen, XG ;
Fan, LY ;
Hu, Z .
ELECTROPHORESIS, 2004, 25 (23-24) :3962-3969
[6]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[7]  
Gas B, 2002, ELECTROPHORESIS, V23, P3520, DOI 10.1002/1522-2683(200210)23:20<3520::AID-ELPS3520>3.0.CO
[8]  
2-G
[9]   Reversed-phase capillary liquid chromatography coupled on-line to capillary electrophoresis immunoassays [J].
German, I ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5365-5372
[10]   Separation of enantiomers in capillary electrophoresis with contactless conductivity detection [J].
Gong, XY ;
Kubán, P ;
Tanyanyiwa, J ;
Hauser, PC .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (02) :230-234