The combination of flow injection with electrophoresis using capillaries and chips

被引:26
作者
Chen, XG [1 ]
Fan, LY [1 ]
Hu, Z [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Peoples R China
关键词
capillary electrophoresis; flow injection; microfluidic chip; miniaturization; review;
D O I
10.1002/elps.200406134
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The combined flow injection capillary electrophoresis (FI-CE) system that integrates the essential favorable merits of FI and CE, can significantly expand the application scope of CE by exploring the various on-line sample pretreatments and pre-concentration of FI. The principle behind this technique, some innovative designs of the split-flow interface, as well as novel applications to a variety of analytical problems, are reviewed and discussed. Some salient features and unique advantages of this technique are outlined.
引用
收藏
页码:3962 / 3969
页数:8
相关论文
共 53 条
[1]   SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS [J].
ALBIN, M ;
GROSSMAN, PD ;
MORING, SE .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :A489-A497
[2]   Determination of anti-carcinogenic polyphenols present in green tea using capillary electrophoresis coupled to a flow injection system [J].
Arce, L ;
Ríos, A ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (01) :113-120
[3]   On-line ion-exchange preconcentration in a flow injection system coupled to capillary electrophoresis for the direct determination of UV absorbing anions [J].
Arce, L ;
Kuban, P ;
Ríos, A ;
Valcárcel, M ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :39-44
[4]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[5]   DETERMINATION OF ANALYTICAL PARAMETERS IN DRINKING-WATER BY FLOW-INJECTION ANALYSIS .1. SIMULTANEOUS DETERMINATION OF PH, ALKALINITY AND TOTAL IONIC CONCENTRATION [J].
CANETE, F ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYST, 1987, 112 (03) :263-266
[6]   Miniaturized capillary electrophoresis system with ultraviolet photometric detection combined with flow injection sample introduction using a modified falling-drop interface [J].
Cao, XD ;
Fang, Q ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2004, 513 (02) :473-479
[7]   On-line conversion and determination of aspirin using a flow injection-capillary electrophoresis system [J].
Chen, HL ;
Fan, LY ;
Chen, XG ;
Hu, ZD ;
Zhao, ZF ;
Hooper, M .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) :863-868
[8]  
Chen HL, 2003, J CHROMATOGR SCI, V41, P1
[9]  
Chen HL, 2002, ELECTROPHORESIS, V23, P2865, DOI 10.1002/1522-2683(200209)23:17&lt
[10]  
2865::AID-ELPS2865&gt