Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading

被引:86
作者
Anderst, William J. [1 ]
Donaldson, William F., III [1 ]
Lee, Joon Y. [1 ]
Kang, James D. [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA 15260 USA
关键词
In vivo; Spine; Kinematics; Mechanics; Helical axis; Range of motion; ADJACENT-SEGMENT-PATHOLOGY; FLEXION-EXTENSION; AXIAL ROTATION; DISC ARTHROPLASTY; SAGITTAL PLANE; INSTANT CENTER; AGING SPINE; MOTION; VALIDATION; FUSION;
D O I
10.1016/j.jbiomech.2015.02.049
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine were collected at 30 images/s as 29 participants (20-35 yr) performed dynamic flexion\extension, axial rotation, and lateral bending. Vertebral motion (C1-T1 in flexion\extension, C3-T1 in lateral bending and axial rotation) was tracked with sub-millimeter accuracy using a validated volumetric model-based tracking process that matched subject-specific CT-based bone models to the radiographs. Flexion\extension ROM was smallest at the C2-C3 motion segment (12.7 +/- 2.6 degrees) and largest at the C5-C6 motion segment (19.7 +/- 3.7 degrees). During head lateral bending and axial rotation, the intervertebral bending ROM was greater than the rotation ROM at every motion segment. The HAM demonstrated differences among motion segments and among movements. During flexion\extension, the helical axis of motion was directed nearly perpendicular to the sagittal plane for the C2-C3 through C7-T1 motion segments. During lateral bending, the angle between the HAM and the transverse plane progressively increased from the C6-C7 motion segment (approximately +/- 22 degrees) to the C3-C4 motion segment (approximately +/- 40 degrees). During axial rotation, the angle between the transverse plane and the HAM was approximately +/- 42 degrees at the C3-C4 through C5-C6 motion segments, and approximately +/- 32 degrees at the C6-C7 motion segment. This study provides valuable reference data for evaluating the effects of age, degeneration, and surgical procedures on cervical spine kinematics during three-dimensional dynamic functional loading. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1286 / 1293
页数:8
相关论文
共 32 条
[1]
INSTANTANEOUS AXES OF ROTATION OF THE TYPICAL CERVICAL MOTION SEGMENTS - A STUDY IN NORMAL VOLUNTEERS [J].
AMEVO, B ;
WORTH, D ;
BOGDUK, N .
CLINICAL BIOMECHANICS, 1991, 6 (02) :111-117
[2]
Motion Path of the Instant Center of Rotation in the Cervical Spine During In Vivo Dynamic Flexion-Extension Implications for Artificial Disc Design and Evaluation of Motion Quality After Arthrodesis [J].
Anderst, William ;
Baillargeon, Emma ;
Donaldson, William ;
Lee, Joon ;
Kang, James .
SPINE, 2013, 38 (10) :E594-E601
[3]
Validation of three-dimensional model-based tibio-femoral tracking during running [J].
Anderst, William ;
Zauel, Roger ;
Bishop, Jennifer ;
Demps, Erinn ;
Tashman, Scott .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) :10-16
[4]
Cervical spine intervertebral kinematics with respect to the head are different during flexion and extension motions [J].
Anderst, William J. ;
Donaldson, William F. ;
Lee, Joon Y. ;
Kang, James D. .
JOURNAL OF BIOMECHANICS, 2013, 46 (08) :1471-1475
[5]
Six-Degrees-of-Freedom Cervical Spine Range of Motion During Dynamic Flexion-Extension After Single-Level Anterior Arthrodesis Comparison with Asymptomatic Control Subjects [J].
Anderst, William J. ;
Lee, Joon Y. ;
Donaldson, William F., III ;
Kang, James D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (06) :497-506
[6]
Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement [J].
Anderst, William J. ;
Baillargeon, Emma ;
Donaldson, William F., III ;
Lee, Joon Y. ;
Kang, James D. .
SPINE, 2011, 36 (06) :E393-E400
[7]
Sensitivity, reliability and accuracy of the instant center of rotation calculation in the cervical spine during in vivo dynamic flexion-extension [J].
Baillargeon, Emma ;
Anderst, William J. .
JOURNAL OF BIOMECHANICS, 2013, 46 (04) :670-676
[8]
Natural history of the aging spine [J].
Benoist, M .
EUROPEAN SPINE JOURNAL, 2003, 12 (Suppl 2) :S86-S89
[9]
Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics [J].
Bey, Michael J. ;
Zauel, Roger ;
Brock, Stephanie K. ;
Tashman, Scott .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :604-609
[10]
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889