Near-infrared Raman spectroscopy to detect anti-Toxoplasma gondii antibodies in blood sera of domestic cats

被引:2
作者
Duarte, J [1 ]
Tadeu, M [1 ]
Pacheco, T [1 ]
Silveira, L [1 ]
Machado, RZ [1 ]
Martins, RA [1 ]
Zangaro, RA [1 ]
Villaverde, AB [1 ]
机构
[1] Univ Vale Paraiba, Inst Pesquisa & Desenvolvimento, BR-12244000 Sao Jose Dos Campos, SP, Brazil
来源
LASERS IN SURGERY: ADVANCED CHARACTERIZATION THERAPEUTICS, AND SYSTEMS XI | 2001年 / 4244卷
关键词
toxoplasmosis; serological analysis; disease diagnosis; NIR Raman spectroscopy; PCA method;
D O I
10.1117/12.427767
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near Infrared (NIR) Raman Spectroscopy has been study for the last years for many biomedical applications. It is a powerful tool for biological materials analysis. Toxoplasmosis is an important zoonosis in public health, being the cats the principal responsible for the transmission of the disease in Brazil. The objective of this work is to investigate a new method of diagnosis of this disease. NIR Raman Spectroscopy was used to detect anti Toxoplasma gondii antibodies in blood sera from domestic cats, without sample preparation. In all, six blood serum samples were used for this study. A previous serological test was done by the Indirect Immunoenzymatic Assay (ELISA) to permit a comparative study between both techniques and it showed that three serum samples were positive and the other three were negative to toxoplasmosis. Raman spectra were taken for all the samples and analyzed by using the Principal Components Analysis (PCA). A diagnosis parameter was defined from the analysis of the second and third principal components of the Raman spectra. It was found that this parameter can detect the infection level of the animal. The results have indicated that NIR Raman Spectroscopy, associated to the PCA can be a promising technique for serological analysis, such as toxoplasmosis, allowing a fast and sensitive method of diagnosis.
引用
收藏
页码:536 / 543
页数:8
相关论文
共 20 条
[11]   Effects of sampling parameters on principal components analysis of Raman line images [J].
Hayden, CA ;
Morris, MD .
APPLIED SPECTROSCOPY, 1996, 50 (06) :708-714
[12]  
Lindsay DS, 1997, COMP CONT EDUC PRACT, V19, P448
[13]   Low-intensity laser light-induced closure of a chronic wound in a dog [J].
Lucroy, MD ;
Edwards, BF ;
Madewell, BR .
VETERINARY SURGERY, 1999, 28 (04) :292-295
[14]  
PUPPELS GJ, 1996, 15 INT C RAM SPECTR, V15, P522
[15]  
QU YJ, 1999, APPL OPTICS, V38, P5491
[16]   Surgery for retinal detachment [J].
Sullivan, TC .
VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 1997, 27 (05) :1193-+
[17]   Prevalence of IgG and IgM antibodies specific to Toxoplasma gondii in cats [J].
Svobodová, V ;
Knotek, Z ;
Svoboda, M .
VETERINARY PARASITOLOGY, 1998, 80 (02) :173-176
[18]  
Torreggiani A, 1998, J RAMAN SPECTROSC, V29, P229, DOI 10.1002/(SICI)1097-4555(199803)29:3<229::AID-JRS229>3.0.CO
[19]  
2-X
[20]   EVALUATION OF POLYNOMIAL FITTING FUNCTIONS FOR USE WITH CCD ARRAYS IN RAMAN-SPECTROSCOPY [J].
WOLLMAN, ST ;