Application of Prussian blue based composite film with functionalized organic polymer to construction of enzymatic glucose biosensor

被引:44
作者
Derwinska, K
Miecznikowski, K
Koncki, R
Kulesza, PJ
Glab, S
Malik, MA
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
[2] Czestochowa Tech Univ, Div Chem, PL-42200 Czestochowa, Poland
关键词
Prussian blue; polymerized 4(pyrrole-1-yl) benzoic acid; composite film; hydrogen peroxide; electrocatalytic reduction; enzyme covalent attachment; sensor; glucose determination; flow injection; pharmaceuticals; food samples;
D O I
10.1002/elan.200302761
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe and characterize an amperometric biosensor utilizing the electrocatalytic reduction of hydrogen peroxide at a glassy carbon electrode modified with a novel composite film of Prussian Blue and polypyrrole derivative, polymerized 4(pyrrole-1-yl) benzoic acid, overcoated with the covalently bound glucose oxidase enzyme. The addition of a functionalized organic component to Prussian Blue permits permanent attachment of an enzyme, exhibits an overall stabilizing effect, and it seems to support fast propagation of charge within the Prussian Blue based composite film. Preliminary diagnostic experiments have been done using cyclic voltammetry, chronocoulometry and rotating disk volatmmetry. The rate of hydrogen peroxide reduction at the composite film in the potassium containing phosphate buffer (pH 6) is expected to be very fast because the overall process is controlled by diffusion of hydrogen peroxide in solution. The fact that the reduction of enzymatically produced hydrogen peroxide proceeds at a fairly negative potential, 0 V (vs. SCE) (pH 6), makes the system largely free of common interferences (e.g., ascorbic acid or uric acid). The proposed biosensor permitted reproducible and reliable determinations of glucose in real (i.e., in pharmaceutical and food) samples also under the flow-injection analysis conditions. The detection limit and sensitivity have been found to be on the level of 1 x 10(-5) mol dm(-3) and 0.7 muA/1 mmol dm(-3) (2.5 muA/cm(2)/1 mmol dm(-3)), respectively.
引用
收藏
页码:1843 / 1849
页数:7
相关论文
共 50 条
[11]  
Dussel H, 1996, FRESEN J ANAL CHEM, V355, P21
[12]   ELECTRON-DIFFUSION IN WET AND DRY PRUSSIAN BLUE FILMS ON INTERDIGITATED ARRAY ELECTRODES [J].
FELDMAN, BJ ;
MURRAY, RW .
INORGANIC CHEMISTRY, 1987, 26 (11) :1702-1708
[13]  
GALUS Z, 1989, FUNDAMENTALS ELECTRO
[14]  
GARIONYTE R, 2000, SENSOR ACTUAT B-CHEM, V63, P122
[15]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[16]   SELECTIVE DETECTION IN FLOW-ANALYSIS BASED ON THE COMBINATION OF IMMOBILIZED ENZYMES AND CHEMICALLY MODIFIED ELECTRODES [J].
GORTON, L ;
CSOREGI, E ;
DOMINGUEZ, E ;
EMNEUS, J ;
JONSSONPETTERSSON, G ;
MARKOVARGA, G ;
PERSSON, B .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :203-248
[17]   ANALYSIS OF ELECTROGENERATED FILMS BY ELLIPSOMETRY AND INFRARED SPECTROMETRY [J].
HAMNETT, A ;
CHRISTENSEN, PA ;
HIGGINS, SJ .
ANALYST, 1994, 119 (05) :735-747
[18]   ELECTROCHEMISTRY OF POLYNUCLEAR TRANSITION-METAL CYANIDES - PRUSSIAN BLUE AND ITS ANALOGS [J].
ITAYA, K ;
UCHIDA, I ;
NEFF, VD .
ACCOUNTS OF CHEMICAL RESEARCH, 1986, 19 (06) :162-168
[19]   Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes .1. [J].
Jaffari, SA ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :1-9
[20]  
KAHN O, 1995, NATURE, V378, P667, DOI 10.1038/378667a0