Nerve regeneration across a 25-mm gap bridged by a polyglycolic acid collagen tube: A histological and electrophysiological evaluation of regenerated nerves

被引:126
作者
Kiyotani, T [1 ]
Teramachi, M [1 ]
Takimoto, Y [1 ]
Nakamura, T [1 ]
Shimizu, Y [1 ]
Endo, K [1 ]
机构
[1] KYOTO UNIV,FAC MED,DEPT PHYSIOL,KYOTO,JAPAN
关键词
peripheral nerve regeneration; polyglycolic acid collagen tube; horseradish peroxidase; somatosensory evoked potential; electromyogram; cat sciatic nerve; intracellular recording from motorneuron; reinnervation; misdirected;
D O I
10.1016/S0006-8993(96)00848-7
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In the study reported here we have examined the nerve regeneration that occurs over a 25-mm gap using a novel biodegradable nerve guide tube. The tube was a composite of polyglycolic acid (PGA) mesh coated with collagen which was filled with neurotrophic factors. The left sciatic nerve of ten adult cats was dissected. The stumps were connected by the tuber and fixed gap. Histological examinations carried out 4-16 months after implantation of the tubs revealed regeneration of well vascularized nerve tissue. Regeneration of both myelinated, unmyelinated axons and Schwann cells was confirmed by electron microscopy 5 months after surgery. Following injection of horseradish peroxidase (HRP) into a site peripheral to the regenerated segment of the sciatic nerves, motoneurons in the ventral horn of the spinal cord, afferent terminals in the medial portion of the dorsal column of the medulla oblongata, and sensory afferent nerve terminals in the dorsal horn of the spinal cord were labelled. Electrophysiological examinations revealed restoration of evoked electromyograms and sensory evoked potentials (SEPs) recorded from the cerebral cortex as well as the spinal cord. We also found that some of the regenerated motor axons exhibited branching in the regenerated segments. In two cases, a single motoneuronal axon from the regenerated side projected to both flexors and extensors. simultaneously. Our results indicate that the PGA-collagen composite tube is a promising tool for use as a nerve guide tube in peripheral nerve regeneration.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 24 条
[11]   PERIPHERAL-NERVE REPAIR ACROSS A GAP STUDIED BY REPEATED OBSERVATION IN A NEW WINDOW IMPLANT CHAMBER [J].
HUMPHREY, MF ;
LEVY, WJ ;
DIETRICH, WD ;
RUMPF, R ;
MORA, J .
BRAIN RESEARCH, 1989, 497 (01) :132-137
[12]   AN ELECTROPHYSIOLOGICAL STUDY OF EARLY STAGES OF PERIPHERAL NERVE REGENERATION [J].
JACOBSON, S ;
GUTH, L .
EXPERIMENTAL NEUROLOGY, 1965, 11 (01) :48-&
[13]  
Lee G., 1993, Japanese Journal of Artificial Organs, V22, P364
[14]   NEURONOTROPHIC ACTIVITIES ACCUMULATE INVIVO WITHIN SILICONE NERVE REGENERATION CHAMBERS [J].
LONGO, FM ;
MANTHORPE, M ;
SKAPER, SD ;
LUNDBORG, G ;
VARON, S .
BRAIN RESEARCH, 1983, 261 (01) :109-116
[15]   NERVE REGENERATION IN SILICONE CHAMBERS - INFLUENCE OF GAP LENGTH AND OF DISTAL STUMP COMPONENTS [J].
LUNDBORG, G ;
DAHLIN, LB ;
DANIELSEN, N ;
GELBERMAN, RH ;
LONGO, FM ;
POWELL, HC ;
VARON, S .
EXPERIMENTAL NEUROLOGY, 1982, 76 (02) :361-375
[16]   CLINICAL NERVE RECONSTRUCTION WITH A BIOABSORBABLE POLYGLYCOLIC ACID TUBE [J].
MACKINNON, SE ;
DELLON, AL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 85 (03) :419-424
[17]   COMPLICATIONS FROM SILICON POLYMER INTUBULATION OF NERVES [J].
MERLE, M ;
DELLON, AL ;
CAMPBELL, JN ;
CHANG, PS .
MICROSURGERY, 1989, 10 (02) :130-133
[18]  
OKUMURA N, 1994, ASAIO J, V40, P834
[19]  
OLMOS JD, 1977, NEUROSCI LETT, V6, P107
[20]   ACCURACY OF REINNERVATION BY PERIPHERAL-NERVE AXONS REGENERATING ACROSS A 10-MM GAP WITHIN AN IMPERMEABLE CHAMBER [J].
RENDE, M ;
GRANATO, A ;
LOMONACO, M ;
ZELANO, G ;
TOESCA, A .
EXPERIMENTAL NEUROLOGY, 1991, 111 (03) :332-339