IL-4 and IL-13 mRNA real-time PCR quantification on whole blood to assess allergic response

被引:19
作者
Ocmant, A
Michils, A
Schandené, L
Peignois, Y
Goldman, M
Stordeur, P
机构
[1] Univ Libre Bruxelles, Hop Erasme, Dept Immunol Hematol Transfus, B-1070 Brussels, Belgium
[2] Univ Libre Bruxelles, Hop Erasme, Dept Pneumol, Brussels, Belgium
[3] Univ Libre Bruxelles, Inst Med Immunol, B-6041 Charleroi, Belgium
关键词
allergy; IgE; real-time PCR; IL-4; IL-3;
D O I
10.1016/j.cyto.2005.06.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Although routinely used in clinical practice, skin prick tests and serum specific IgE often fail to distinguish between IgE-sensitization and symptomatic IgE-mediated allergy. There is therefore a need for new laboratory tests relating allergic symptoms to the offending agent. In this way, we evaluated the diagnostic reliability of a new whole blood quantitative real-time PCR assay for IL-4 and IL-13 mRNAs. We compared the response of cat allergic patients and non-cat allergic controls upon anti-IgE and cat allergen (Fel d1) stimulation of whole blood. Allergen addition led to a significant increase of IL-4 and IL-13 mRNAs in allergic patients compared to non-allergic controls (p < 0.0001). Both cytokine mRNA levels were strongly correlated and peaked within 2 h after Fel d1 or anti-IgE addition. This rapid increase as well as purification experiments led us to the conclusion that basophils represent an important if not the main source of both transcripts in this setting. The effect was allergen-specific since not observed when stimulating blood from cat allergic patients with birch pollen. Interestingly, we found that IFN-gamma mRNA, contrary to IL-4 mRNA, reached higher levels in response to Fel d1 with control individuals than with patients allergic to cat. This study shows that whole blood real-time PCR is a valuable method for IL-4 and IL-13 mRNA measurement after in vitro allergen challenge. We suggest that it might be useful, complementing conventional markers, for the diagnosis and the follow-up of allergic diseases. Further assessments are required to evaluate the clinical potential of this technique. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 17 条
[11]   Quantitative real-time PCR: a powerful ally in cancer research [J].
Mocellin, S ;
Rossi, CR ;
Pilatil, P ;
Nitti, D ;
Marincola, FM .
TRENDS IN MOLECULAR MEDICINE, 2003, 9 (05) :189-195
[12]   Quantitative detection of T-cell activation markers by real-time PCR in renal transplant rejection and correlation with histopathologic evaluation [J].
Sabek, M ;
Dorak, MT ;
Kotb, M ;
Gaber, AO ;
Gaber, L .
TRANSPLANTATION, 2002, 74 (05) :701-707
[13]  
Sampson HA, 2001, J ALLERGY CLIN IMMUN, V107, P891, DOI 10.1067/mai.2001.114708
[14]   Immune monitoring in whole blood using real-time PCR [J].
Stordeur, P ;
Zhou, L ;
Byl, B ;
Brohet, F ;
Burny, W ;
de Groote, D ;
van der Poll, T ;
Goldman, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 276 (1-2) :69-77
[15]   Cytokine mRNA quantification by real-time PCR (vol 259, pg 55, 2002) [J].
Stordeur, P ;
Poulin, LF ;
Craciun, L ;
Zhou, L ;
Schandené, L ;
de Lavareille, A ;
Goriely, S ;
Goldman, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 262 (1-2) :229-229
[16]   Analysis of spontaneous mRNA cytokine production in peripheral blood [J].
Stordeur, P ;
Zhou, L ;
Goldman, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 261 (1-2) :195-197
[17]  
Teramoto T, 1998, CLIN EXP ALLERGY, V28, P74