Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial

被引:205
作者
Conraads, Viviane M. [1 ]
Tavazzi, Luigi [2 ]
Santini, Massimo [3 ]
Oliva, Fabrizio [4 ]
Gerritse, Bart [5 ]
Yu, Cheuk-Man [6 ]
Cowie, Martin R. [7 ]
机构
[1] Univ Antwerp Hosp, Dept Cardiol, B-2650 Edegem, Belgium
[2] Villa Maria Cecilia Hosp, GVM, Cotignola, Italy
[3] Azienda Osped San Filippo Neri, Rome, Italy
[4] Azienda Osped Niguarda Ca Granda, Milan, Italy
[5] Medtron Bakken Res Ctr, Maastricht, Netherlands
[6] Chinese Univ Hong Kong, Prince Wales Hosp, Hong Kong, Hong Kong, Peoples R China
[7] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
关键词
Bioelectrical impedance monitoring; Chronic heart failure (HF); Decompensation; Hospitalization; Diagnosis; DIAGNOSTICS IDENTIFY PATIENTS; HEMODYNAMIC MONITOR; RATE-VARIABILITY; RISK; CARE; DETERIORATION; RATIONALE;
D O I
10.1093/eurheartj/ehr050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Early recognition of impending decompensation and timely intervention may prevent heart failure (HF) hospitalization. We investigated the performance of OptiVolw intrathoracic fluid monitoring for the prediction of HF events in chronic HF patients newly implanted with a device (implantable cardioverter-defibrillator with or without cardiac resynchronization therapy). Methods and results SENSE-HF was a prospective, multi-centre study that enrolled 501 patients. Phase I (double blinded, 6 months) determined the sensitivity and positive predictive value (PPV) of the OptiVol data in predicting HF hospitalizations. Of 58 adjudicated HF hospitalizations that occurred during the first 6 months in Phase I, 12 were predicted by OptiVol (sensitivity = 20.7%). Sensitivity appeared to be dynamic in nature and at the end of Phase I, had increased to 42.1%. With 253 OptiVol detections, PPV for Phase I was 4.7%. Phase II/III (unblinded, 18 months) determined the PPV of the first OptiVol Patient Alert for detection of worsening HF status with signs and/or symptoms of pulmonary congestion. A total of 233 patients noted such an OptiVol alert and for 210, HF status was evaluated within 30 days. Heart failure status had worsened for 80 patients (PPV = 38.1%). Conclusions An intrathoracic impedance-derived fluid index had low sensitivity and PPV in the early period after implantation of a device in chronic HF patients. Sensitivity improved within the first 6 months after implant. Further studies are needed to assess the place of this monitoring technology in the clinical management of patients with HF.
引用
收藏
页码:2266 / 2273
页数:8
相关论文
共 26 条
[1]   Superior Performance of Intrathoracic Impedance-Derived fluid Index versus Daily Weight monitoring in Heart Failure Patients: Results of the Fluid Accumulation Status Trial (FAST) [J].
Abraham, William T. ;
Compton, Steven ;
Haas, Garlic ;
Foreman, Blair ;
Canby, Robert C. ;
Fishel, Robert ;
McRae, Scott ;
Toledo, Gloria B. ;
Sarkar, Shantanu .
JOURNAL OF CARDIAC FAILURE, 2009, 15 (09) :813-813
[2]   Continuous autonomic assessment in patients with symptomatic heart failure - Prognostic value of heart rate variability measured by an implanted cardiac resynchronization device [J].
Adamson, PB ;
Smith, AL ;
Abraham, WT ;
Kleckner, KJ ;
Stadler, RW ;
Shih, A ;
Rhodes, MM .
CIRCULATION, 2004, 110 (16) :2389-2394
[3]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[4]   Monitoring of physical activity and heart rate variability in patients with chronic heart failure using cardiac resynchronization devices [J].
Braunschweig, F ;
Mortensen, PT ;
Gras, D ;
Reiser, W ;
Lawo, T ;
Mansour, H ;
Sogaard, P ;
Stegemann, B ;
Bruns, HJ ;
Linde, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (09) :1104-1107
[5]   Can monitoring of intrathoracic impedance reduce morbidity and mortality in patients with chronic heart failure? Rationale and design of the Diagnostic Outcome Trial in Heart Failure (DOT-HF) [J].
Braunschweig, Frieder ;
Ford, Ian ;
Conraads, Viviane ;
Cowie, Martin R. ;
Jondeau, Guillaume ;
Kautzner, Josef ;
Lunati, Maurizio ;
Aguilera, Roberto Munoz ;
Yu, Cheuk Man ;
Marijianowskii, Monique ;
Borggrefe, Martin ;
van Veldhuisen, Dirk J. .
EUROPEAN JOURNAL OF HEART FAILURE, 2008, 10 (09) :907-916
[6]   The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) study: Rationale and design [J].
Burri, Haran ;
Quesada, Aurelio ;
Ricci, Renato Pietro ;
Boriani, Giuseppe ;
Davinelli, Mario ;
Favale, Stefano ;
Da Costa, Antoine ;
Kautzner, Josef ;
Moser, Raymond ;
Navarro, Xavier ;
Santini, Massimo .
AMERICAN HEART JOURNAL, 2010, 160 (01) :42-48
[7]   Monitoring Intrathoracic Impedance with an Implantable Defibrillator Reduces Hospitalizations in Patients with Heart Failure [J].
Catanzariti, Domenico ;
Lunati, Maurizio ;
Landolina, Maurizio ;
Zanotto, Gabriele ;
Lonardi, Gabriele ;
Iacopino, Saverio ;
Oliva, Fabrizio ;
Perego, Giovanni B. ;
Varbaro, Annamaria ;
Denaro, Alessandra ;
Valsecchi, Sergio ;
Vergara, Giuseppe .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (03) :363-370
[8]   Noninvasive home telemonitoring for patients with heart failure at high risk of recurrent admission and death - The trans-European network-home-care management system (TEN-HMS) study [J].
Cleland, JGF ;
Louis, AA ;
Rigby, AS ;
Janssens, U ;
Balk, AHMM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (10) :1654-1664
[9]   The pathophysiology of acute heart failure - Is it all about fluid accumulation? [J].
Cotter, Gad ;
Felker, G. Michael ;
Adams, Kirkwood F. ;
Milo-Cotter, Olga ;
O'Connor, Christopher M. .
AMERICAN HEART JOURNAL, 2008, 155 (01) :9-18
[10]   Rationale and Design of a Prospective Trial to Assess the Sensitivity and Positive Predictive Value of Implantable Intrathoracic Impedance Monitoring in the Prediction of Heart Failure Hospitalizations: The SENSE-HF Study [J].
Cowie, Martin R. ;
Conraads, Vivianne ;
Tavazzi, Luigi ;
Yu, C. M. .
JOURNAL OF CARDIAC FAILURE, 2009, 15 (05) :394-400