High power transcranial beam steering for ultrasonic brain therapy

被引:164
作者
Pernot, M [1 ]
Aubry, JF [1 ]
Tanter, M [1 ]
Thomas, JL [1 ]
Fink, M [1 ]
机构
[1] Univ Paris 07, ESPCI, Lab Ondes & Acoustique, CNRS,UMR 7587, F-75005 Paris, France
关键词
D O I
10.1088/0031-9155/48/16/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A sparse phased array is specially designed for non-invasive ultrasound transskull brain therapy. The array is made of 200 single elements corresponding to a new generation of high power transducers developed in collaboration with Imasonic (Besancon, France). Each element has a surface of 0.5 cm(2) and works at 0.9 MHz central frequency with a maximum 20 W cm(-2) intensity on the transducer surface. In order to optimize the steering capabilities of the array, several transducer distributions on a spherical surface are simulated: hexagonal, annular and quasi-random distributions. Using a quasi-random distribution significantly reduces the grating lobes. Furthermore, the simulations show the capability of the quasi-random array to electronically move the focal spot in the vicinity of the geometrical focus (up to +/-15 mm). Based on the simulation study, the array is constructed and tested. The skull aberrations are corrected by using a time reversal mirror with amplitude correction achieved thanks to an implantable hydrophone, and a sharp focus is obtained through a human skull. Several lesions are induced in fresh liver and brain samples through human skulls, demonstrating the accuracy and the steering capabilities of the system.
引用
收藏
页码:2577 / 2589
页数:13
相关论文
共 26 条
[1]   Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans [J].
Aubry, JF ;
Tanter, M ;
Pernot, M ;
Thomas, JL ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :84-93
[2]   SIMPLE METHOD FOR PRODUCTION OF TRACKLESS FOCAL LESIONS WITH FOCUSED ULTRASOUND - STATISTICAL EVALUATION OF EFFECTS OF IRRADIATION ON CENTRAL NERVOUS SYSTEM OF CAT [J].
BASAURI, L ;
LELE, PP .
JOURNAL OF PHYSIOLOGY-LONDON, 1962, 160 (03) :513-&
[3]   COMPUTATION OF THE IMPULSE DIFFRACTION OF ANY OBSTACLE BY IMPULSE RAY MODELING - PREDICTION OF THE SIGNAL DISTORTIONS [J].
CASSEREAU, D ;
GUYOMAR, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (04) :1504-1516
[4]   New piezoelectric transducers for therapeutic ultrasound [J].
Chapelon, JY ;
Cathigol, D ;
Cain, C ;
Ebbini, E ;
Kluiwstra, JU ;
Sapozhnikov, OA ;
Fleury, G ;
Berriet, R ;
Chupin, L ;
Guey, JL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (01) :153-159
[5]   Investigation of a large-area phased array for focused ultrasound surgery through the skull [J].
Clement, GT ;
White, J ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :1071-1083
[6]   A non-invasive method for focusing ultrasound through the human skull [J].
Clement, GT ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1219-1236
[7]   Micro-receiver guided transcranial beam steering [J].
Clement, GT ;
Hynynen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (04) :447-453
[8]   A hemisphere array for non-invasive ultrasound brain therapy and surgery [J].
Clement, GT ;
Sun, J ;
Giesecke, T ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3707-3719
[9]   ULTRASONIC THRESHOLD DOSAGES FOR MAMMALIAN CENTRAL NERVOUS SYSTEM [J].
DUNN, F ;
FRY, FJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1971, BM18 (04) :253-&
[10]   Reduction of the grating lobes of annular arrays used in focused ultrasound surgery [J].
Dupenloup, F ;
Chapelon, JY ;
Cathignol, DJ ;
Sapozhnikov, OA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (06) :991-998