Biomechanical Comparison of Locking versus Nonlocking Volar and Dorsal T-Plates for Fixation of Dorsally Comminuted Distal Radius Fractures

被引:24
作者
Gondusky, Joseph S. [1 ]
Carney, Joseph [1 ]
Erpenbach, Jonathan [1 ]
Robertson, Claire [2 ]
Mahar, Andrew [2 ,3 ]
Oka, Richard [2 ]
Thompson, Michael [1 ]
Mazurek, Michael
机构
[1] Balboa Naval Med Ctr San Diego, Dept Orthopaed Surg, San Diego, CA USA
[2] Rady Childrens Hosp San Diego, Orthoped Biomech Res Ctr, San Diego, CA USA
[3] Univ Calif San Diego, Dept Orthoped Surg, San Diego, CA 92103 USA
关键词
distal radius fracture; volar plate; dorsal plate; dorsal comminution; extra-articular; biomechanical; INTERNAL-FIXATION; DISPLACED FRACTURES; EXTERNAL FIXATION; COMPRESSION PLATE; RADIOULNAR JOINT; OPEN REDUCTION; PI PLATE; PC-FIX; MODEL; STABILITY;
D O I
10.1097/BOT.0b013e3181d7a3a6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objectives: The purpose of this study was to gain insight into the effect of plate location and screw type for fixation of extra-articular distal radius fractures with dorsal comminution (Orthopaedic Trauma Association Type 23-A3.2). Methods: Sixteen pairs of cadaver radii were randomized to four plating configurations: dorsal locking, dorsal nonlocking, volar locking, and volar nonlocking. A standard 1-cm dorsal wedge osteotomy was used. Cyclic axial loads were applied for 5000 cycles. Stiffness and fragment displacement were recorded at 500 cycle-intervals. Pre- and postcyclic loading radiographs were analyzed. An axial load to failure test followed and construct stiffness and failure strength recorded. Biomechanical data were analyzed using a two-way analysis of variance (P<0.05). Failure modes were descriptively interpreted. Results: Cyclic testing data revealed no difference between constructs at any interval. Within all construct groups, displacement that occurred did so within the first 500 cycles of testing. Pre- and postcyclic loading radiographic analysis showed no differences in construct deformation. Load to failure testing revealed no differences between groups, whereas volar constructs approached significance (P = 0.08) for increased failure strength. Dorsal constructs failed primarily by fragment subsidence and fragmentation, whereas volar constructs failed by plate bending. Conclusions: No difference in all measured biomechanical parameters supports equivalence between constructs and surgeon discretion in determining operative method. Minimal fragment displacement and construct deformation during physiological testing support previous data that early postoperative motion can be recommended. Fragment displacement that occurs does so in the early periods of motion.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 36 条
[1]
OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[2]
RELATIVE TENSION AND POTENTIAL EXCURSION OF MUSCLES IN THE FOREARM AND HAND [J].
BRAND, PW ;
THOMPSON, DE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (03) :209-219
[3]
Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[4]
Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures [J].
Chiang, PP ;
Roach, S ;
Baratz, ME .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (04) :724-728
[5]
Dunning CE, 1999, J HAND SURG-AM, V24A, P992
[6]
Frigg R, 2001, INJURY, V32, pSB63
[7]
DESIGN AND BIOMECHANICS OF A PLATE FOR THE DISTAL RADIUS [J].
GESENSWAY, D ;
PUTNAM, MD ;
MENTE, PL ;
LEWIS, JL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (06) :1021-1027
[8]
FORCE DISTRIBUTION ACROSS WRIST JOINT - APPLICATION OF PRESSURE-SENSITIVE CONDUCTIVE RUBBER [J].
HARA, T ;
HORII, E ;
AN, KN ;
COONEY, WP ;
LINSCHEID, RL ;
CHAO, EYS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (02) :339-347
[9]
Kamano M, 2002, CLIN ORTHOP RELAT R, P403
[10]
Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741