Biomechanical Comparison of Locking versus Nonlocking Volar and Dorsal T-Plates for Fixation of Dorsally Comminuted Distal Radius Fractures

被引:24
作者
Gondusky, Joseph S. [1 ]
Carney, Joseph [1 ]
Erpenbach, Jonathan [1 ]
Robertson, Claire [2 ]
Mahar, Andrew [2 ,3 ]
Oka, Richard [2 ]
Thompson, Michael [1 ]
Mazurek, Michael
机构
[1] Balboa Naval Med Ctr San Diego, Dept Orthopaed Surg, San Diego, CA USA
[2] Rady Childrens Hosp San Diego, Orthoped Biomech Res Ctr, San Diego, CA USA
[3] Univ Calif San Diego, Dept Orthoped Surg, San Diego, CA 92103 USA
关键词
distal radius fracture; volar plate; dorsal plate; dorsal comminution; extra-articular; biomechanical; INTERNAL-FIXATION; DISPLACED FRACTURES; EXTERNAL FIXATION; COMPRESSION PLATE; RADIOULNAR JOINT; OPEN REDUCTION; PI PLATE; PC-FIX; MODEL; STABILITY;
D O I
10.1097/BOT.0b013e3181d7a3a6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objectives: The purpose of this study was to gain insight into the effect of plate location and screw type for fixation of extra-articular distal radius fractures with dorsal comminution (Orthopaedic Trauma Association Type 23-A3.2). Methods: Sixteen pairs of cadaver radii were randomized to four plating configurations: dorsal locking, dorsal nonlocking, volar locking, and volar nonlocking. A standard 1-cm dorsal wedge osteotomy was used. Cyclic axial loads were applied for 5000 cycles. Stiffness and fragment displacement were recorded at 500 cycle-intervals. Pre- and postcyclic loading radiographs were analyzed. An axial load to failure test followed and construct stiffness and failure strength recorded. Biomechanical data were analyzed using a two-way analysis of variance (P<0.05). Failure modes were descriptively interpreted. Results: Cyclic testing data revealed no difference between constructs at any interval. Within all construct groups, displacement that occurred did so within the first 500 cycles of testing. Pre- and postcyclic loading radiographic analysis showed no differences in construct deformation. Load to failure testing revealed no differences between groups, whereas volar constructs approached significance (P = 0.08) for increased failure strength. Dorsal constructs failed primarily by fragment subsidence and fragmentation, whereas volar constructs failed by plate bending. Conclusions: No difference in all measured biomechanical parameters supports equivalence between constructs and surgeon discretion in determining operative method. Minimal fragment displacement and construct deformation during physiological testing support previous data that early postoperative motion can be recommended. Fragment displacement that occurs does so in the early periods of motion.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 36 条
[11]
Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture? a biomechanical study [J].
Kandemir, Utku ;
Matityahu, Amir ;
Desai, Rohan ;
Puttlitz, Christian .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) :605-610
[12]
Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model [J].
Leung, F ;
Zhu, L ;
Ho, H ;
Lu, WW ;
Chow, SP .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (03) :263-266
[13]
A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures [J].
Liporace, FA ;
Gupta, S ;
Jeong, GK ;
Stracher, M ;
Kummer, F ;
Egol, KA ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) :187-191
[14]
A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model [J].
Liporace, Frank Anthony ;
Kubiak, Erik N. ;
Jeong, Gerard K. ;
Iesaka, Kazuho ;
Egol, Kenneth A. ;
Koval, Kenneth J. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (03) :668-672
[15]
Lowry K J, 2000, Am J Orthop (Belle Mead NJ), V29, P789
[16]
Complications in internal fixation of the distal radius [J].
Lucas, GL ;
Fejfar, ST .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (06) :1117-1117
[17]
INTRAOPERATIVE ASSESSMENT OF WRIST EXTENSOR MUSCLE FORCE [J].
MENDELSON, LS ;
PECKHAM, PH ;
FREEHAFER, AA ;
KEITH, MW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06) :832-836
[18]
Plating of the distal radius [J].
Nana, AD ;
Joshi, A ;
Lichtman, DM .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (03) :159-171
[19]
Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report [J].
Orbay, JL ;
Fernandez, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02) :205-215
[20]
Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study [J].
Osada, D ;
Viegas, SF ;
Shah, MA ;
Morris, RP ;
Patterson, RM .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01) :94-104