Solvent optimization is an important procedure in desorption electrospray ionization (DESI) and in this study the effects of solvent surface tension are explored. Data are presented for methanol/water/surfactant solvent systems, which show increases in ion signals of more than an order of magnitude when low concentrations of surfactants are added to the standard methanol/water (1:1) spray solvent. Examples of analytes tested include food chemicals, peptides, pharmaceuticals, and drugs of abuse. The improvement in ion intensity is mainly attributed to the effect of surface tension in producing smaller spray droplets, which are shown to cover a larger surface area. Surfactant-containing spray solutions allowed extension of DESI-MS analysis to previously intractable analytes like melamine and highly hydrophobic compounds like the sudan dyes. (J Am Soc Mass Spectrom 2010, 21, 1423-1431) (C) 2010 American Society for Mass Spectrometry
引用
收藏
页码:1423 / 1431
页数:9
相关论文
共 42 条
[21]   Scanning and surface alignment considerations in chemical imaging with desorption electrospray mass spectrometry [J].
Kertesz, Vilmos ;
van Berkel, Gary J. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1027-1032
[22]  
KISSA E, 2001, SURFACTANT SCI, V97, P350
[23]   Desorption electrospray ionization mass spectrometry: direct toxicological screening and analysis of illicit Ecstasy tablets [J].
Leuthold, LA ;
Mandscheff, JF ;
Fathi, M ;
Giroud, C ;
Augsburger, M ;
Varesio, E ;
Hopfgartner, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (02) :103-110
[24]   Direct quantification of PAHs in biomass burning aerosols by desorption electrospray ionization mass spectrometry [J].
Li, Mei ;
Chen, Hong ;
Wang, Bi-Fei ;
Yang, Xin ;
Lian, Jin-Jun ;
Chen, Jian-Min .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 281 (1-2) :31-36
[25]  
LORIAU M, 2009, P ASMS
[26]   Desorption electrospray ionization (DESI) mass Spectrometry and tandem mass spectrometry (MS/MS) of phospholipids and sphingolipids: Ionization, adduct formation, and fragmentation [J].
Manicke, Nicholas E. ;
Wiseman, Justin M. ;
Ifa, Demian R. ;
Cooks, R. Graham .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (04) :531-543
[27]   Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments [J].
McEwen, CN ;
McKay, RG ;
Larsen, BS .
ANALYTICAL CHEMISTRY, 2005, 77 (23) :7826-7831
[28]   Development of a dielectric barrier discharge ion source for ambient mass spectrometry [J].
Na, Na ;
Zhao, Mengxia ;
Zhang, Sichun ;
Yang, Chengdui ;
Zhang, Xinrong .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (10) :1859-1862
[29]   Molecular dynamics simulation of surfactin molecules at the water-hexane interface [J].
Nicolas, JP .
BIOPHYSICAL JOURNAL, 2003, 85 (03) :1377-1391
[30]   Reactive desorption electrospray ionization linear ion trap mass spectrometry of latest-generation counterfeit antimalarials via noncovalent complex formation [J].
Nyadong, Leonard ;
Green, Michael D. ;
De Jesus, Victor R. ;
Newton, Paul N. ;
Fernandez, Facundo M. .
ANALYTICAL CHEMISTRY, 2007, 79 (05) :2150-2157