Protein contact printing for a surface plasmon resonance biosensor with on-chip referencing

被引:51
作者
Lu, HB
Homola, J
Campbell, CT
Nenninger, GG
Yee, SS
Ratner, BD [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Chem, Seattle, WA 98195 USA
[4] Univ Washington, Dept Chem Engn, Seattle, WA 98195 USA
关键词
surface plasmon resonance (SPR); protein contact printing; biosensors; protein patterning;
D O I
10.1016/S0925-4005(00)00716-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Protein contact printing (pCP) has been applied to locally functionalize a novel wavelength-modulated single flow channel surface plasmon resonance (SPR) sensor with an on-chip reference. The SPR sensor has a high refractive index dielectric tantalum pentoxide (Ta2O5) overlayer covering part of the gold sensing surface to generate a SPR resonance (SPR-Ta) that is spectrally-separated from the resonance of the Ta2O5-free Au resonance (SPR-Au). Thus, an on-chip reference channel is provided [Electron. Lett. 35 (1999) 1105]. This communication demonstrates that pCP can be used for functionalizing such dual-channel SPR sensors. By using pCP bovine serum albumin (BSA) was shown to passivate the surfaces well enough to prevent non-specific protein adsorption. In contrast, the printed 2,4-dinitrophenylated BSA (DNP-BSA) was recognized specifically by anti-dinitrophenyl antibodies (alpha -DNP) in solution. By printing DNPBSA and BSA onto the Au and Ta2O5 surfaces, respectively, we demonstrate that the reversible bulk refractive index changes presented in both signals can be canceled out. Therefore, a more accurate binding curve for the alpha -DNP/DNP interaction can be obtained by subtracting the properly scaled SPR-Ta reference signal from the SPR-Au signal. We show that pCP is a simple, efficient, and versatile method for delivering multiple proteins with sufficient surface coverage and activity onto such sensor surfaces without cross-interference to adjacent areas. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 21 条
[11]   Patterned protein layers on solid substrates by thin stamp microcontact printing [J].
James, CD ;
Davis, RC ;
Kam, L ;
Craighead, HG ;
Isaacson, M ;
Turner, JN ;
Shain, W .
LANGMUIR, 1998, 14 (04) :741-744
[12]   Quantitative interpretation of the response of surface plasmon resonance sensors to adsorbed films [J].
Jung, LS ;
Campbell, CT ;
Chinowsky, TM ;
Mar, MN ;
Yee, SS .
LANGMUIR, 1998, 14 (19) :5636-5648
[13]   First-order surface plasmon resonance sensor system based on a planar light pipe [J].
Karlsen, SP ;
Johnston, KS ;
Yee, SS ;
Jung, CC .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (02) :137-141
[14]   RADIATIVE DECAY OF NON RADIATIVE SURFACE PLASMONS EXCITED BY LIGHT [J].
KRETSCHM.E ;
RAETHER, H .
ZEITSCHRIFT FUR NATURFORSCHUNG PART A-ASTROPHYSIK PHYSIK UND PHYSIKALISCHE CHEMIE, 1968, A 23 (12) :2135-&
[15]  
LIDE DR, 1990, HDB CHEM PHYSICS
[16]   Attachment of functionalized poly(ethylene glycol) films to gold surfaces [J].
Lu, HB ;
Campbell, CT ;
Castner, DG .
LANGMUIR, 2000, 16 (04) :1711-1718
[17]   Reference-compensated biosensing using a dual-channel surface plasmon resonance sensor system based on a planar lightpipe configuration [J].
Nenninger, GG ;
Clendenning, JB ;
Furlong, CE ;
Yee, SS .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :38-45
[18]   SPR biosensors: simultaneously removing thermal and bulk-composition effects [J].
O'Brien, MJ ;
Brueck, SRJ ;
Perez-Luna, VH ;
Tender, LM ;
Lopez, GP .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (02) :145-154
[19]   Optimization of biosensing using grating couplers: Immobilization on tantalum oxide waveguides [J].
Polzius, R ;
Schneider, T ;
Bier, FF ;
Bilitewski, U ;
Koschinski, W .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (05) :503-514
[20]   Diffraction-based cell detection using a microcontact printed antibody grating [J].
St John, PM ;
Davis, R ;
Cady, N ;
Czajka, J ;
Batt, CA ;
Craighead, HG .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1108-1111