Simple linear formulation for magnetostimulation specific to MRI gradient coils

被引:33
作者
Chronik, BA
Rutt, BK
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 5K8, Canada
关键词
gradient coils; magnetostimulation; nerve; linear; rheobase; chronaxie;
D O I
10.1002/mrm.1121
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A simple linear formulation for magnetostimulation thresholds specific to MRI gradient coils is derived based on established hyperbolic electrostimulation strength vs. duration relations. Thresholds are derived in terms of the gradient excursion required to cause stimulation, and it is demonstrated that the threshold curve is a linear function of the gradient switching time. A parameter 6 is introduced as being fundamental in the evaluation of gradient coil stimulation, 6 is a map of the induced electric field per unit gradient slew rate, and can be calculated directly from the gradient coil wire pattern. Consideration of beta alone is sufficient to compare stimulation thresholds between different gradient coil designs, as well as to evaluate the expected dependency of stimulation threshold on position within the gradient coil. The linear gradient threshold curve is characterized by two parameters: SRmin and DeltaG(min). SRmin is the slope of the threshold curve and represents the minimum stew rate required to cause stimulation in the limit of infinite gradient strength, DeltaG(min) is the vertical axis intercept of the curve and represents the minimum gradient excursion required to cause stimulation in the limit of infinite slew rate. Both SRmin and DeltaG(min) are functions of both beta and the standard tissue parameters E-r (rheobase) and tau (c) (chronaxie time). The ease with which both the gradient system performance and the stimulation thresholds can be plotted on the same axes is noted and is used to introduce the concept of a piece-wise linear operational limit curve for a gradient system. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:916 / 919
页数:4
相关论文
共 22 条
[1]   Peripheral nerve stimulation by time-varying magnetic fields [J].
Abart, J ;
Eberhardt, K ;
Fischer, H ;
Huk, W ;
Richter, E ;
Schmitt, F ;
Storch, T ;
Zeitler, E .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :532-538
[2]  
Bourland JD, 1999, NEUROIMAG CLIN N AM, V9, P363
[3]   ANALYSIS OF THE DISTRIBUTION OF CURRENTS INDUCED BY A CHANGING MAGNETIC-FIELD IN A VOLUME CONDUCTOR [J].
BRANSTON, NM ;
TOFTS, PS .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (02) :161-168
[4]   PHYSIOLOGICAL-EFFECTS OF FAST OSCILLATING MAGNETIC-FIELD GRADIENTS [J].
BUDINGER, TF ;
FISCHER, H ;
HENTSCHEL, D ;
REINFELDER, HE ;
SCHMITT, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) :909-914
[5]   SENSORY STIMULATION BY TIME-VARYING MAGNETIC-FIELDS [J].
COHEN, MS ;
WEISSKOFF, RM ;
RZEDZIAN, RR ;
KANTOR, HL .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :409-414
[6]  
Fischer H., 1998, ECHO PLANAR IMAGING, P201
[7]  
Gandhi OP, 1999, MAGN RESON MED, V41, P816, DOI 10.1002/(SICI)1522-2594(199904)41:4<816::AID-MRM22>3.0.CO
[8]  
2-5
[9]   Peripheral nerve stimulation during MRI: Effects of high gradient amplitudes and switching rates [J].
Ham, CLG ;
Engels, JML ;
vandeWiel, GT ;
Machielsen, A .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :933-937
[10]   AVOIDING PERIPHERAL-NERVE STIMULATION - GRADIENT WAVE-FORM CRITERIA FOR OPTIMUM RESOLUTION IN ECHO-PLANAR IMAGING [J].
HARVEY, PR ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) :236-241