T2-based segmentation of periventricular volumes for quantification of proton magnetic resonance spectra of multiple sclerosis lesions

被引:11
作者
Helms, G [1 ]
机构
[1] Karolinska Hosp, MR Res Ctr, Dept Clin Neurosci, Stockholm, Sweden
[2] Huddinge Univ Hosp, Div Neurol, Karolinska Inst, Stockholm, Sweden
[3] Univ Klinikum Tubingen, Sekt Expt Radiol, D-72076 Tubingen, Germany
关键词
T2; relaxation; magnetic resonance spectroscopy; quantification; cerebrospinal fluid; multiple sclerosis;
D O I
10.1007/s10334-003-0006-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial volume averaging of signal from multiple sclerosis lesions influences biexponential fitting of the water T2 relaxation as used for tissue/CSF segmentation of spectroscopic volumes. Periventricular volumes-of-interest comprising CSF, lesion and normal-appearing white matter in varying proportion were studied. The relaxation of the localized water signal was measured at 12 echo times (STEAM, geometric spacing from 30 ms to 2000 ins, least-squares fit). Magnetization transfer (MT) was applied to identify contributions of tissue signal to the CSF component. The T2 of the long-lived component (T2(long) = 433-1782 ms) and its prolongation after NIT were inversely correlated to the NIT ratio. Hence, short T2(long) is associated with overestimation of CSF partial volume, and thus metabolite concentrations. A T2-correction for the CSF partial volume was suggested and applied to the quantification of MR spectra of large MS lesions. The T2 of bulk CSF (2280 +/- 87 ms) and the influence of the TE sampling scheme were also studied.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 22 条
[11]   Volume correction for edema in single-volume proton MR spectroscopy of contrast-enhancing multiple sclerosis lesions [J].
Helms, G .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :256-263
[12]  
Helms G, 2000, MAGNET RESON MED, V43, P102, DOI 10.1002/(SICI)1522-2594(200001)43:1<102::AID-MRM12>3.0.CO
[13]  
2-I
[14]   ABSOLUTE QUANTITATION OF WATER AND METABOLITES IN THE HUMAN BRAIN .2. METABOLITE CONCENTRATIONS [J].
KREIS, R ;
ERNST, T ;
ROSS, BD .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 102 (01) :9-19
[15]   IN-VIVO VISUALIZATION OF MYELIN WATER IN BRAIN BY MAGNETIC-RESONANCE [J].
MACKAY, A ;
WHITTALL, K ;
ADLER, J ;
LI, D ;
PATY, D ;
GRAEB, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :673-677
[16]  
PIRINGER A, 1998, THESIS STOCKHOLM U
[17]  
PROVENCHER SW, 1976, J CHEM PHYS, V64, P2773
[18]   ESTIMATION OF METABOLITE CONCENTRATIONS FROM LOCALIZED IN-VIVO PROTON NMR-SPECTRA [J].
PROVENCHER, SW .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) :672-679
[19]   AUTOMATED SINGLE-VOXEL PROTON MRS - TECHNICAL DEVELOPMENT AND MULTISITE VERIFICATION [J].
WEBB, PG ;
SAILASUTA, N ;
KOHLER, SJ ;
RAIDY, T ;
MOATS, RA ;
HURD, RE .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :365-373
[20]  
Whittall KP, 1999, MAGNET RESON MED, V41, P1255, DOI 10.1002/(SICI)1522-2594(199906)41:6<1255::AID-MRM23>3.0.CO