Effect of surface parameters on the performance of IgG-arrayed hydrogel chips: A comprehensive study

被引:6
作者
Derwinska, Katarzyna
Gheber, Levi A.
Sauer, Ursula
Schorn, Leopold
Preininger, Claudia [1 ]
机构
[1] Austrian Res Ctr GmbH, ARC, Dept Bioresources, A-2444 Seibersdorf, Austria
[2] Austrian Res Ctr GmbH, ARC, Dept Mat Res, A-2444 Seibersdorf, Austria
[3] Ben Gurion Univ Negev, Dept Biotechnol Engn, IL-84105 Beer Sheva, Israel
关键词
D O I
10.1021/la700608c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this article, the assay performance of 3D polyurethane (PU) hydrogel surfaces, used either plain or modified with cross linkers and additives in a direct immunoassay for IgG, is correlated with chip surface parameters such as water content and expansion, mechanical stability, hydrophilicity, thickness, and surface topography. Commercial chip surfaces ARChip Epoxy, Nexterion slide H and HydroGel are used as references. A strong correlation between assay sensitivity and physical surface parameters was found only for various hydrogels of the same chemical composition, in which cases assay sensitivity increases with decreasing hydrogel concentration as well as decreasing roughness, water content, and expansion. However, as is the case with all hydrogels tested, more hydrophobic layers with low water content are more highly reproducible from one measurement to another.
引用
收藏
页码:10551 / 10558
页数:8
相关论文
共 29 条
[1]   Toward optimized antibody microarrays:: a comparison of current microarray support materials [J].
Angenendt, P ;
Glökler, J ;
Murphy, D ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :253-260
[2]   Advances in functional protein microarray technology [J].
Bertone, P ;
Snyder, M .
FEBS JOURNAL, 2005, 272 (21) :5400-5411
[3]   Protein-sensing assay formats and devices [J].
Bilitewski, Ursula .
ANALYTICA CHIMICA ACTA, 2006, 568 (1-2) :232-247
[4]   Immobilization strategy and characterization of hydrogel-based thin films for interrogation of ligand binding with staphylococcal enterotoxin B (SEB) in a protein microarray format [J].
Charles, PT ;
Taitt, CR ;
Goldman, ER ;
Rangasammy, JG ;
Stenger, DA .
LANGMUIR, 2004, 20 (01) :270-272
[5]   Protein and peptide arrays: Recent trends and new directions [J].
Cretich, M ;
Damin, F ;
Pirri, G ;
Chiari, M .
BIOMOLECULAR ENGINEERING, 2006, 23 (2-3) :77-88
[6]   A new polymeric coating for protein microarrays [J].
Cretich, M ;
Pirri, G ;
Damin, F ;
Solinas, I ;
Chiari, M .
ANALYTICAL BIOCHEMISTRY, 2004, 332 (01) :67-74
[7]   Characterization of an inexpensive, nontoxic, and highly sensitive microarray substrate [J].
Dufva, M ;
Petronis, S ;
Jensen, LB ;
Krag, C ;
Christensen, CBV .
BIOTECHNIQUES, 2004, 37 (02) :286-+
[8]  
Feilner Tanja, 2004, Current Proteomics, V1, P283
[9]   Detection of proteins cross-linked within galactoside polyacrylate-based hydrogels by means of a quantum dot fluororeagent [J].
Goldman, ER ;
O'Shaughnessy, TJ ;
Soto, CM ;
Patterson, CH ;
Taitt, CR ;
Spector, MS ;
Charles, PT .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (7-8) :880-886
[10]   Methods and applications of antibody microarrays in cancer research [J].
Haab, BB .
PROTEOMICS, 2003, 3 (11) :2116-2122