Accuracy of stereotactic localisation with magnetic resonance compared to CT scan: Experimental findings

被引:32
作者
Landi, A
Marina, R
DeGrandi, C
Crespi, A
Montanari, G
Sganzerla, EP
Gaini, SM
机构
[1] Univ Milan, Inst Neurosurg, Bicocca, Italy
[2] Osped San Gerardo, Dept Neuroradiol, Monza, Italy
[3] Osped San Gerardo, Dept Med Phys, Monza, Italy
关键词
stereotactic surgery; MRI; CT; accuracy;
D O I
10.1007/s007010170064
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background. Stereotactic localisation of proper targets can be obtained with Magnetic Resonance imaging (MRI). pending correction of the well-known inaccuracy of MRI in reproducing exact geometrical dimension. The aim of the experimental work was to determine the real extent of the MRI distortion and to correct it. Methods. PVC phantoms and fixed human brains were used as target simulators; stereotactic targeting was obtained with CT and MRI: the results were compared and, finally. the real stereotactic values were measured on a commercial stereotactic device. To optimise MRI targeting it was necessary to abate the "chemical-shift", to modify the head-coil receiver (tuning the "off-resonance" frequencies) and to correct the targeting directly on the images (especially for the Y axis values). careful quality control and environmental tests were also necessary to maintain good performances along the time. Results. 172 measurements were carried out using both CT, plain X-ray and MRI on PVC phantom. The values obtained from CT were considered as reference. Significant geometrical accuracy was found with CT targeting, except for the Z co-ordinate, due to the slice thickness. Mean value differences between the targets on MRI and their real geometric position are about 1 mm on X and Z axises and about 2 mm on Y axis. Similar results were obtained on fixed brains, where absolute values of X and Y co-ordinates of the simulators were measured using a millimetre grid placed over the brain slice. Interpretation. Experimental findings concerning stereotactic targeting with MRI suggest accuracy adequate for clinical practice. even when extreme geometrical precision is required. such as in radiosurgery or functional stereotaxy. Careful quality control and intensive experimental setting of the MRT device are mandatory to obtain satisfactory results.
引用
收藏
页码:593 / 601
页数:9
相关论文
共 37 条
[1]   MAGNETIC-RESONANCE IMAGE-DIRECTED STEREOTAXIC NEUROSURGERY - USE OF IMAGE FUSION WITH COMPUTERIZED-TOMOGRAPHY TO ENHANCE SPATIAL ACCURACY [J].
ALEXANDER, E ;
KOOY, HM ;
VANHERK, M ;
SCHWARTZ, M ;
BARNES, PD ;
TARBELL, N ;
MULKERN, RV ;
HOLUPKA, EJ ;
LOEFFLER, JS .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :271-276
[2]   MODIFIED SOLUTION FOR FILLING MRI COORDINATE INDICATORS FOR THE ZD STEREOTAXIC FRAME [J].
ALP, MS ;
LUER, MS ;
MISRA, M ;
DUJOVNY, M ;
AUSMAN, JI .
NEUROLOGICAL RESEARCH, 1995, 17 (04) :295-296
[3]   STEREOTAXIC VENTROLATERAL THALAMOTOMY - IS VENTRICULOGRAPHY NECESSARY [J].
ALTERMAN, RL ;
KALL, BA ;
COHEN, H ;
KELLY, PJ .
NEUROSURGERY, 1995, 37 (04) :717-721
[4]  
BENABID LA, 1993, ACTA NEUROCHIR WIE S, V58, P39
[5]   CONTROL OF TREMOR AND INVOLUNTARY MOVEMENT-DISORDERS BY CHRONIC STEREOTAXIC STIMULATION OF THE VENTRAL INTERMEDIATE THALAMIC NUCLEUS [J].
BLOND, S ;
CAPARROSLEFEBVRE, D ;
PARKER, F ;
ASSAKER, R ;
PETIT, H ;
GUIEU, JD ;
CHRISTIAENS, JL .
JOURNAL OF NEUROSURGERY, 1992, 77 (01) :62-68
[6]  
Bradford R, 1987, Acta Neurochir Suppl (Wien), V39, P25
[7]   VARIABLES AFFECTING THE ACCURACY OF STEREOTAXIC LOCALIZATION USING COMPUTERIZED-TOMOGRAPHY [J].
BUCHOLZ, RD ;
HO, HW ;
RUBIN, JP .
JOURNAL OF NEUROSURGERY, 1993, 79 (05) :667-673
[8]   EFFECTS OF COREGISTRATION OF MR TO CT IMAGES ON MR STEREOTAXIC ACCURACY [J].
COHEN, DS ;
LUSTGARTEN, JH ;
MILLER, E ;
KHANDJI, AG ;
GOODMAN, RR .
JOURNAL OF NEUROSURGERY, 1995, 82 (05) :772-779
[9]   Optimizing accuracy in magnetic resonance imaging-guided stereotaxis: a technique with validation based on the anterior commissure-posterior commissure line [J].
diPierro, CG ;
Francel, PC ;
Jackson, TR ;
Kamiryo, T ;
Laws, ER .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :94-100
[10]  
DORMONT D, 1994, AM J NEURORADIOL, V15, P365