Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial

被引:252
作者
Krak, NC
Boellaard, R
Hoekstra, OS
Twisk, JWR
Hoekstra, CJ
Lammertsma, AA [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Clin PET Ctr, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Clin Epidemiol & Biostat, Amsterdam, Netherlands
关键词
D O I
10.1007/s00259-004-1566-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Quantitative measurement of tracer uptake in a tumour can be influenced by a number of factors, including the method of defining regions of interest (ROIs) and the reconstruction parameters used. The main purpose of this study was to determine the effects of different ROI methods on quantitative outcome, using two reconstruction methods and the standard uptake value (SUV) as a simple quantitative measure of FDG uptake. Methods: Four commonly used methods of ROI definition (manual placement, fixed dimensions, threshold based and maximum pixel value) were used to calculate SUV (SUV[MAN], SUV15 mm, SUV50, SUV75 and SUVmax, respectively) and to generate "metabolic" tumour volumes. Test-retest reproducibility of SUVs and of "metabolic" tumour volumes and the applicability of ROI methods during chemotherapy were assessed. In addition, SUVs calculated on ordered subsets expectation maximisation (OSEM) and filtered back-projection (FBP) images were compared. Results: ROI definition had a direct effect on quantitative outcome. On average, SUV[MAN], SUV15 mm, SUV50 and SUV75, were respectively 48%, 27%, 34% and 15% lower than SUVmax when calculated on OSEM images. No statistically significant differences were found between SUVs calculated on OSEM and FBP reconstructed images. Highest reproducibility was found for SUV15 mm and SUV[MAN] (ICC 0.95 and 0.94, respectively) and for "metabolic" volumes measured with the manual and 50% threshold ROIs (ICC 0.99 for both). Manual, 75% threshold and maximum pixel ROIs could be used throughout therapy, regardless of changes in tumour uptake or geometry. SUVs showed the same trend in relative change in FDG uptake after chemotherapy, irrespective of the ROI method used. Conclusion: The method of ROI definition has a direct influence on quantitative outcome. In terms of simplicity, user-independence, reproducibility and general applicability the threshold-based and fixed dimension methods are the best ROI methods. Threshold methods are in addition relatively independent of changes in size and geometry, however, and may therefore be more suitable for response monitoring purposes.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 35 条
[21]   Attenuation correction in whole-body FDG oncological studies: the role of statistical reconstruction [J].
Lonneux, M ;
Borbath, I ;
Bol, A ;
Coppens, A ;
Sibomana, M ;
Bausart, R ;
Defrise, M ;
Pauwels, S ;
Michel, C .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (06) :591-598
[22]  
Mankoff DA, 2003, J NUCL MED, V44, P1806
[23]   LUNG-CANCER - REPRODUCIBILITY OF QUANTITATIVE MEASUREMENTS FOR EVALUATING 2-[F-18]-FLUORO-2-DEOXY-D-GLUCOSE UPTAKE AT PET [J].
MINN, H ;
ZASADNY, KR ;
QUINT, LE ;
WAHL, RL .
RADIOLOGY, 1995, 196 (01) :167-173
[24]  
Nakamoto Yuji, 2002, Mol Imaging Biol, V4, P171, DOI 10.1016/S1536-1632(01)00004-X
[25]   FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection [J].
Ramos, CD ;
Erdi, YE ;
Gonen, M ;
Riedel, E ;
Yeung, HWD ;
Macapinlac, HA ;
Chisin, R ;
Larson, SM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (02) :155-164
[26]  
Römer W, 1998, BLOOD, V91, P4464
[27]   Positron emission tomography using [18F]fluorodeoxyglucose for monitoring primary chemotherapy in breast cancer [J].
Schelling, M ;
Avril, N ;
Nährig, J ;
Kuhn, W ;
Römer, W ;
Sattler, D ;
Werner, M ;
Dose, J ;
Jänicke, F ;
Graeff, H ;
Schwaiger, M .
JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (08) :1689-1695
[28]   Positron emission tomography using [18F]-fluorodeoxy-D-glucose to predict the pathologic response of breast cancer to primary chemotherapy [J].
Smith, IC ;
Welch, AE ;
Hutcheon, AW ;
Miller, ID ;
Payne, S ;
Chilcott, F ;
Waikar, S ;
Whitaker, T ;
Ah-See, AK ;
Eremin, O ;
Heys, SD ;
Gilbert, FJ ;
Sharp, PF .
JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (08) :1676-1688
[29]   Reevaluation of the standardized uptake value for FDG: Variations with body weight and methods for correction [J].
Sugawara, Y ;
Zasadny, KR ;
Neuhoff, AW ;
Wahl, RL .
RADIOLOGY, 1999, 213 (02) :521-525
[30]   Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [18F]FDG PET [J].
Visvikis, D ;
Cheze-LeRest, C ;
Costa, DC ;
Bomanji, J ;
Gacinovic, S ;
Ell, PJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (09) :1326-1335