Accuracy of automated blood pressure recorders in pregnancy

被引:11
作者
Brown, MA [1 ]
Robinson, A [1 ]
Buddle, ML [1 ]
机构
[1] St George Hosp, Dept Renal Med, Kogarah, NSW 2217, Australia
关键词
D O I
10.1111/j.1479-828X.1998.tb03062.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated blood pressure recorders are used with increasing frequency by pregnant women, mostly without proper evaluation of their accuracy. We compared blood pressures (BP) recorded by 2 automated noninvasive devices, the Spacelabs 90207 ambulatory blood pressure monitor and the OMRON HEM 705 CP portable selfinitiated device, with blood pressures recorded by routine sphygmomanometry in 79 pregnant women either considered 'at risk' for preeclampsia or,with mild hypertension in pregnancy. The Spacelabs device tended to overestimate systolic BP by a mean 11 (SD=8) mmHg and diastolic BP by 5 (SD=7) mmHg for phase 5 pressure (p<0.001) but was similar to routine BPs for diastolic phase 4 pressures. The OMRON device tended to underestimate diastolic (phase 4) pressure by 4 (SD=6) mmHg (p<0.001) but gave similar systolic and diastolic (phase 5) pressures to routine sphygmomanometry. However, for both devices there was considerable individual patient variability in accuracy. When using these devices to record a limited number of blood pressure recordings, as in this study, we suggest that individual comparison with mercury sphygmomanometry be made in each pregnant woman before accepting the validity of these recordings.
引用
收藏
页码:262 / 265
页数:4
相关论文
共 11 条
[1]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[2]   DIVERSITY OF BLOOD-PRESSURE RECORDING DURING PREGNANCY - IMPLICATIONS FOR THE HYPERTENSIVE DISORDERS [J].
BROWN, MA ;
SIMPSON, JM .
MEDICAL JOURNAL OF AUSTRALIA, 1992, 156 (05) :306-308
[3]   Accuracy of oscillometric blood pressure monitoring in pregnancy and pre-eclampsia [J].
Gupta, M ;
Shennan, AH ;
Halligan, A ;
Taylor, DJ ;
deSwiet, M .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (03) :350-355
[4]   AMBULATORY BLOOD-PRESSURE MEASUREMENT IN PREGNANCY - THE CURRENT STATE-OF-THE-ART [J].
HALLIGAN, A ;
SHENNAN, A ;
THURSTON, H ;
DESWIET, M ;
TAYLOR, D .
HYPERTENSION IN PREGNANCY, 1995, 14 (01) :1-16
[5]   INDIRECT BLOOD-PRESSURE MEASUREMENT IN PREGNANCY - KOROTKOFF PHASE 4 VERSUS PHASE 5 [J].
JOHENNING, AR ;
BARRON, WM .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 167 (03) :577-580
[6]   AN OUTLINE OF THE REVISED BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF BLOOD-PRESSURE MEASURING DEVICES [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
ALTMAN, DG ;
BLAND, M ;
COATS, A ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1993, 11 (06) :677-679
[7]   THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
OMALLEY, K ;
JAMIESON, M ;
ALTMAN, D ;
BLAND, M ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1990, 8 (07) :607-619
[8]   Validation of the Welch Allyn QuietTrak ambulatory blood pressure monitor in pregnancy [J].
Penny, JA ;
Shennan, AH ;
Rushbrook, J ;
Halligan, AW ;
Taylor, DJ ;
deSwiet, M .
HYPERTENSION IN PREGNANCY, 1996, 15 (03) :313-321
[9]   CONFLICTING VIEWS ON THE MEASUREMENT OF BLOOD-PRESSURE IN PREGNANCY [J].
PERRY, IJ ;
WILKINSON, LS ;
SHINTON, RA ;
BEEVERS, DG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (03) :241-243
[10]   Measuring diastolic blood pressure in pregnancy [J].
Rubin, P .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :4-5