Sequential-injection analysis (SIA): A useful tool for on-line sample-handling and pre-treatment

被引:100
作者
Economou, A [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
dilution; enzymatic analysis; extraction; gas diffusion; immunological analysis; sequential-injection analysis;
D O I
10.1016/j.trac.2004.12.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, sequential-injection analysis (SIA) is reviewed as a tool for on-line sample manipulation and sample pre-treatment. Although SIA is an established technique for performing solution chemistry, its great potential lies in the scope it offers for the more complicated on-line sample-manipulation stages before the measurement step. This review will demonstrate the scope of SIA in complex sample-handling procedures with examples of online sample dilution, dialysis and gas diffusion, extraction (liquid/liquid, gas/liquid and solid-phase), enzymatic and immunological assays, and various other on-line operations. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:416 / 425
页数:10
相关论文
共 58 条
[51]   Immunologic trapping in supported liquid membrane extraction [J].
Thordarson, E ;
Jönsson, JÅ ;
Emnéus, J .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5280-5284
[52]   Sequential fluorometric quantification of malic acid enantiomers by a single line flow-injection system using immobilized-enzyme reactors [J].
Tsukatani, T ;
Matsumoto, K .
TALANTA, 2005, 65 (02) :396-401
[53]   On-line separation, simultaneous dilution and spectrophotometric determination of zinc in fertilisers with a sequential injection system and xylenol orange as complexing agent [J].
van Staden, JF ;
Tlowana, SI .
TALANTA, 2002, 58 (06) :1115-1122
[54]   Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry [J].
Wang, JH ;
Hansen, EH .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :283-292
[55]   Interfacing sequential injection on-line preconcentration using a renewable micro-column incorporated in a 'lab-on-valve' system with direct injection nebulization inductively coupled plasma mass spectrometry [J].
Wang, JH ;
Hansen, EH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1349-1355
[56]   Micro sequential injection: automated insulin derivatization and separation using a lab-on-valve capillary electrophoresis system [J].
Wu, CH ;
Scampavia, L ;
Ruzicka, J .
ANALYST, 2003, 128 (09) :1123-1130
[57]   On-line coupling of sequential injection with liquid chromatography for the automated derivatization and determination of γ-aminobutyric acid in human biological fluids [J].
Zacharis, CK ;
Theodoridis, GA ;
Voulgaropoulos, AN .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02) :169-175
[58]   Determination of thiamine in pharmaceutical preparations by sequential injection renewable surface solid-phase spectrofluorometry [J].
Zhu, HL ;
Chen, HW ;
Zhou, YL .
ANALYTICAL SCIENCES, 2003, 19 (02) :289-294