Capillary electrophoresis system with flow injection sample introduction and chemiluminescence detection on a chip platform

被引:64
作者
Huang, XJ
Pu, QS
Fang, ZL
机构
[1] Northeastern Univ, Analyt Sci Res Ctr, Shenyang 110006, Peoples R China
[2] Zhejiang Univ, Inst Microanalyt Syst, Hangzhou 310027, Peoples R China
关键词
D O I
10.1039/b008857i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrophoresis (CE) system with chemiluminescence (CL) detection was combined with flow injection (FI) sample introduction on a chip platform. A falling-drop interface was applied to perform FI split-flow sample introduction while achieving electrical isolation from the CE high voltage. A tubular reservoir at the capillary outlet served as both the CL reaction and detection cell for the luminol-peroxide-metallic ion chemiluminescent reaction, with the luminol included in the separation buffer and CL reagent H2O2 continuously introduced into the outlet reservoir. An optical fiber was positioned within the outlet reservoir directly opposite, and 300 mum away from, the capillary outlet for collecting and transferring the generated CL to the PMT. The peak height signals and the separation efficiency were almost independent of the reagent flow-rate, making the system a robust one. The performance of the system was illustrated by the separation of Co(II) and Cu(II), achieving baseline separation in 60 s. Detection limits (3 sigma) were 1.25 x 10(-8) and 2.3 x 10(-6) mol dm(-3) for Co(II) and Cu(II), respectively. Peak height precision was 1.9% RSD (n = 9) at the 10(-7) mol dm(-3) Co level.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 25 条
[1]   Determination of codeine, 6-methoxycodeine and thebaine using capillary electrophoresis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW ;
Purcell, SD .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :321-324
[2]   Combination of flow injection with capillary electrophoresis. Part 3. On-line sorption column preconcentration capillary electrophoresis system [J].
Chen, HW ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) :135-143
[3]   Combination of flow injection with capillary electrophoresis - Part 4. Automated multicomponent monitoring of drug dissolution [J].
Chen, HW ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1998, 376 (02) :209-220
[4]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[5]  
Dadoo R., 1992, J HIGH RES CHROMATOG, V15, P133
[6]   Fabrication of metallic microstructures using exposed, developed silver halide-based photographic film [J].
Deng, T ;
Arias, F ;
Ismagilov, RF ;
Kenis, PJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :645-651
[7]   Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system [J].
Fang, Q ;
Wang, FR ;
Wang, SL ;
Liu, SS ;
Xu, SK ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :27-37
[8]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[9]   Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection [J].
Fu, CG ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :71-79
[10]   SEPARATION AND DETECTION OF PROTEIN AS A SUPRAMOLECULAR COMPLEX USING CAPILLARY ELECTROPHORESIS [J].
Hara, Tadashi ;
Okamura, Shinobu ;
Kato, Shigeru ;
Yokogi, Junichi ;
Nakajima, Riichiro .
ANALYTICAL SCIENCES, 1991, 7 :261-264