Clinical Evaluation of Zero-Echo-Time MR Imaging for the Segmentation of the Skull

被引:106
作者
Delso, Gaspar [1 ]
Wiesinger, Florian [2 ]
Sacolick, Laura I. [2 ]
Kaushik, Sandeep S. [3 ]
Shanbhag, Dattesh D. [3 ]
Huellner, Martin [4 ]
Veit-Haibach, Patrick [4 ]
机构
[1] GE Healthcare, MR Applicat & Workflow, Waukesha, WI USA
[2] GE Global Res, Munich, Germany
[3] GE Global Res, Bangalore, Karnataka, India
[4] Univ Zurich Hosp, Dept Med Imaging, CH-8091 Zurich, Switzerland
关键词
ZTE; bone; PET/MR; attenuation; skull; ATTENUATION-CORRECTION; MAGNETIC-RESONANCE; PET/MRI; BRAIN; BONE; ATLAS;
D O I
10.2967/jnumed.114.149997
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR-based attenuation correction is instrumental for integrated PET/MR imaging. It is generally achieved by segmenting MR images into a set of tissue classes with known attenuation properties (e.g., air, lung, bone, fat, soft tissue). Bone identification with MR imaging is, however, quite challenging, because of the low proton density and fast decay time of bone tissue. The clinical evaluation of a novel, recently published method for zero-echo-time (ZTE)-based MR bone depiction and segmentation in the head is presented here. Methods: A new paradigm for MR imaging bone segmentation, based on proton density-weighted ZTE imaging, was disclosed earlier in 2014. In this study, we reviewed the bone maps obtained with this method on 15 clinical datasets acquired with a PET/CT/MR trimodality setup. The CT scans acquired for PET attenuation-correction purposes were used as reference for the evaluation. Quantitative measurements based on the Jaccard distance between ZTE and CT bone masks and qualitative scoring of anatomic accuracy by an experienced radiologist and nuclear medicine physician were performed. Results: The average Jaccard distance between ZTE and CT bone masks evaluated over the entire head was 52% +/- 6% (range, 38%-63%). When only the cranium was considered, the distance was 39% +/- 4% (range, 32%-49%). These results surpass previously reported attempts with dualecho ultrashort echo time, for which the Jaccard distance was in the 47%-79% range (parietal and nasal regions, respectively). Anatomically, the calvaria is consistently well segmented, with frequent but isolated voxel misclassifications. Air cavity walls and bone/fluid interfaces with high anatomic detail, such as the inner ear, remain a challenge. Conclusion: This is the first, to our knowledge, clinical evaluation of skull bone identification based on a ZTE sequence. The results suggest that proton density-weighted ZTE imaging is an efficient means of obtaining high-resolution maps of bone tissue with sufficient anatomic accuracy for, for example, PET attenuation correction.
引用
收藏
页码:417 / 422
页数:6
相关论文
共 29 条
[1]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[2]   MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence [J].
Berker, Yannick ;
Franke, Jochen ;
Salomon, Andre ;
Palmowski, Moritz ;
Donker, Henk C. W. ;
Temur, Yavuz ;
Mottaghy, Felix M. ;
Kuhl, Christiane ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Kiessling, Fabian ;
Schulz, Volkmar .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :796-804
[3]  
Catana C, 2010, P INT SOC MAG RESON, V18, P3953
[4]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[5]   Segmentation-Based MR Attenuation Correction Including Bones Also Affects Quantitation in Brain Studies: An Initial Result of 18F-FP-CIT PET/MR for Patients with Parkinsonism [J].
Choi, Hongyoon ;
Cheon, Gi Jeong ;
Kim, Han-Joon ;
Choi, Seung Hong ;
Lee, Jae Sung ;
Kim, Yong-il ;
Kang, Keon Wook ;
Chung, June-Key ;
Kim, E. Edmund ;
Lee, Dong Soo .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (10) :1617-1622
[6]   Cluster-based segmentation of dual-echo ultra-short echo time images for PET/MR bone localization [J].
Delso G. ;
Zeimpekis K. ;
Carl M. ;
Wiesinger F. ;
Hüllner M. ;
Veit-Haibach P. .
EJNMMI Physics, 1 (1) :1-13
[7]   Anatomic Evaluation of 3-Dimensional Ultrashort-Echo-Time Bone Maps for PET/MR Attenuation Correction [J].
Delso, Gaspar ;
Carl, Michael ;
Wiesinger, Florian ;
Sacolick, Laura ;
Porto, Miguel ;
Huellner, Martin ;
Boss, Andreas ;
Veit-Haibach, Patrick .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (05) :780-785
[8]   Short T2 contrast with three-dimensional ultrashort echo time imaging [J].
Du, Jiang ;
Bydder, Mark ;
Takahashi, Atsushi M. ;
Carl, Michael ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IMAGING, 2011, 29 (04) :470-482
[9]   Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone [J].
Du, Jiang ;
Carl, Michael ;
Bydder, Mark ;
Takahashi, Atsushi ;
Chung, Christine B. ;
Bydder, Graeme M. .
JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) :304-311
[10]  
Gibiino F, 2014, MAGMA