Novel power converter topology for three-phase four-wire hybrid power filter

被引:49
作者
Jou, H. -L. [1 ]
Wu, K. -D. [1 ]
Wu, J. -C. [2 ]
Li, C. -H. [1 ]
Huang, M. -S. [3 ]
机构
[1] Natl Kaohsiung Univ Appl Sci, Dept Elect Engn, Kaohsiung 80778, Taiwan
[2] Natl Kaohsuing Marine Univ, Dept Microelect Engn, Kaohsiung 81143, Taiwan
[3] UIS Abler Elect Co Ltd, Kaohsiung 80780, Taiwan
关键词
D O I
10.1049/iet-pel:20070171
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel power converter topology for three-phase four-wire hybrid power filter is proposed. It is configured by a three-arm bridge structure without split capacitors. The salient feature of the three-phase four-wire hybrid power filter using the proposed power converter is that it permits the neutral line of the utility directly connecting to the negative or positive terminal of the DC capacitor located in the DC side of the power converter. Consequently, the power converter uses less number of power electronic switches to reduce the manufacturing cost. A three-phase four-wire hybrid power filter prototype is developed and tested to demonstrate the performance of the three-phase four-wire hybrid power filter using the proposed power converter. Experimental results show that the proposed three-phase four-wire hybrid power filter using the proposed power converter has the expected performance.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 19 条
[1]   Hybrid solutions for improving passive filter performance in high power applications [J].
Bhattacharya, S ;
Cheng, PT ;
Divan, DM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :732-747
[2]  
CHENG PT, 2001, NEW HARMONIC SUPPRES, P1287
[3]   Parallel operation of capacity-limited three-phase four-wire active power filters [J].
Chiang, SJ ;
Ai, WJ ;
Lin, FJ .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (05) :329-336
[4]   Odd-harmonic digital repetitive control of a single-phase current active filter [J].
Costa-Castelló, R ;
Griñó, R ;
Fossas, E .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (04) :1060-1068
[5]  
DIXON J, 2000, SIMPLE CONTROL SCHEM, P991
[6]   A PRACTICAL APPROACH TO HARMONIC COMPENSATION IN POWER-SYSTEMS - SERIES CONNECTION OF PASSIVE AND ACTIVE-FILTERS [J].
FUJITA, H ;
AKAGI, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (06) :1020-1025
[7]  
JIN T, 2004, CONTROL TOPOLOGIES 3, V2, P450
[8]   Analysis of Zig-Zag transformer applying in the three-phase four-wire distribution power system [J].
Jou, HL ;
Wu, JC ;
Wu, KD ;
Chiang, WJ ;
Chen, YH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1168-1173
[9]   Parallel operation of passive power filter and hybrid power filter for harmonic suppression [J].
Jou, HL ;
Wu, JC ;
Wu, KD .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (01) :8-14
[10]  
KIM S, 2000, CONTROL STRATEGIES A, P420