摘要
Improvements of CdTe crystal quality and significant progress in the growth of large ingots of high resistivity CdZnTe material enable the fabrication of larger area detectors in single element form or monolithic arrays. These advances allow for the development of imaging devices of improved spatial resolution for industrial, research and medical applications. CdTe and CdZnTe detectors operate in single photon counting mode or in current mode (charge integrating mode). The paper presents advantages of CdTe and CdZnTe over common scintillator type detectors, but also presents the shortcomings of the former detectors with respect to charge collection which limit the yields of good spectrometers. The paper reviews industrial and research applications utilizing these detectors and in particular describes in detail two imaging systems for security screening and custom inspection. These systems are characterized by large dynamic range and good spatial resolution and are composed of large arrays of CdTe spectrometers and discriminator grade detectors. A wide energy range detector assembly, for astrophysical research of gamma ray bursts composed of CdTe, HgI2 and CdZnTe spectrometers in two dimensional arrays is also presented.
引用
收藏
页码:431 / 439
页数:9
相关论文
共 25 条
[1]   OVERVIEW OF THE USE OF CDTE DETECTORS FOR THE VERIFICATION OF NUCLEAR MATERIAL IN NUCLEAR SAFEGUARDS [J].
ARLT, R ;
CZOCK, KH ;
RUNDQUIST, DE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :575-582
[2]   SEMICONDUCTOR ARRAYS WITH MULTIPLEXER READOUT FOR GAMMA-RAY IMAGING - RESULTS FOR A 48X48 GE ARRAY [J].
BARBER, HB ;
AUGUSTINE, FL ;
BARRETT, HH ;
DERENIAK, EL ;
MATHERSON, KL ;
MEYERS, TJ ;
PERRY, DL ;
VENZON, JE ;
WOOLFENDEN, JM ;
YOUNG, ET .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :361-365
[3]   A CDTE GAMMA-RAY SPECTROMETER WITH IMAGING CAPABILITIES FOR ASTROPHYSICS - MONTE-CARLO SIMULATION RESULTS [J].
CAROLI, E ;
BALDAZZI, G ;
DICOCCO, G ;
DONATI, A ;
DUSI, W ;
MALAGUTI, G ;
ROSSI, M ;
STEPHEN, JB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :639-643
[4]   PIXELLATED CDZNTE DETECTOR ARRAYS [J].
DOTY, FP ;
BARBER, HB ;
AUGUSTINE, FL ;
BUTLER, JF ;
APOTOVSKY, BA ;
YOUNG, ET ;
HAMILTON, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :356-360
[5]  
EISEN Y, 1993, MATER RES SOC SYMP P, V302, P487, DOI 10.1557/PROC-302-487
[7]   CORRECTION OF INCOMPLETE CHARGE COLLECTION IN CDTE DETECTORS [J].
EISEN, Y ;
HOROVITZ, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :60-66
[8]  
EISEN Y, 1994, UNPUB
[9]  
Fishman G. J., 1989, P GAMMA RAY OBSERVAT, P39
[10]  
GERRISH VM, 1995, PREPRINT