Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system

被引:28
作者
Liao, Chao-Kang [1 ]
Huang, Sheng-Wen [1 ]
Wei, Chen-Wei [1 ]
Li, Pai-Chi [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Grad Inst Biomed Elect & Bioinformat, Taipei 106, Taiwan
关键词
flow rate; high-frame-rate imaging; photoacoustic imaging; nanoparticles; nanorods;
D O I
10.1117/1.2812704
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative flow measurement method that utilizes a sequence of photoacoustic images is described. The method is based on the use of gold nanorods as a contrast agent for photoacoustic imaging. The peak optical absorption wavelength of a gold nanorod depends on its aspect ratio, which can be altered by laser irradiation (we establish a wash-in flow estimation method of this process). The concentration of nanorods with a particular aspect ratio inside a region of interest is affected by both laser-induced shape changes and replenishment of nanorods at a rate determined by the flow velocity. In this study, the concentration is monitored using a custom-designed, high-frame-rate photoacoustic imaging system. This imaging system consists of fiber bundles for wide area laser irradiation, a laser ultrasonic transducer array, and an ultrasound front-end subsystem that allows acoustic data to be acquired simultaneously from 64 transducer elements. Currently, the frame rate of this system is limited by the pulse-repetition frequency of the laser (i.e., 15 Hz). With this system, experimental results from a chicken breast tissue show that flow velocities from 0.125 to 2 mm/s can be measured with an average error of 31.3%. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:9
相关论文
共 40 条
[1]   Connective tissue growth factor-specific antibody attenuates tumor growth, metastasis, and angiogenesis in an orthotopic mouse model of pancreatic cancer [J].
Aikawa, Takuma ;
Gunn, Jason ;
Spong, Suzanne M. ;
Klaus, Stephen J. ;
Korc, Murray .
MOLECULAR CANCER THERAPEUTICS, 2006, 5 (05) :1108-1116
[2]   Assessment of brain tumor angiogenesis inhibitors using perfusion magnetic resonance imaging: Quality and analysis results of a phase I trial [J].
Akella, NS ;
Twieg, DB ;
Mikkelsen, T ;
Hochberg, FH ;
Grossman, S ;
Cloud, GA ;
Nabors, LB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) :913-922
[3]  
Bentzen L, 2000, NMR BIOMED, V13, P429, DOI 10.1002/1099-1492(200012)13:8<429::AID-NBM663>3.0.CO
[4]  
2-K
[5]   Perfusion measurement in acute pancreatitis using dynamic perfusion MDCT [J].
Bize, PE ;
Platon, A ;
Becker, CD ;
Poletti, PA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (01) :114-118
[6]   The shape transition of gold nanorods [J].
Chang, SS ;
Shih, CW ;
Chen, CD ;
Lai, WC ;
Wang, CRC .
LANGMUIR, 1999, 15 (03) :701-709
[7]   A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography [J].
Chen, XC ;
Schwarz, KQ ;
Phillips, D ;
Steinmetz, SD ;
Schlief, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (06) :754-765
[8]   Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent:: an in vitro and in vivo study [J].
Claassen, L ;
Seidel, G ;
Algermissen, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) :83-88
[9]   Bioconjugated gold nanoparticles as a contrast agent for optoacoustic detection of small tumors [J].
Eghtedari, MA ;
Copland, JA ;
Popov, VL ;
Kotov, NA ;
Motamedi, M ;
Oraevsky, AA .
BIOMEDICAL OPTOACOUSTICS IV, 2003, 4960 :76-85
[10]   DIGITAL ANGIOGRAPHIC IMPULSE-RESPONSE ANALYSIS OF REGIONAL MYOCARDIAL PERFUSION - LINEARITY, REPRODUCIBILITY, ACCURACY, AND COMPARISON WITH CONVENTIONAL INDICATOR DILUTION CURVE PARAMETERS IN PHANTOM AND CANINE MODELS [J].
EIGLER, NL ;
PFAFF, JM ;
ZEIHER, A ;
WHITING, JS ;
FORRESTER, JS .
CIRCULATION RESEARCH, 1989, 64 (05) :853-866