Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system

被引:28
作者
Liao, Chao-Kang [1 ]
Huang, Sheng-Wen [1 ]
Wei, Chen-Wei [1 ]
Li, Pai-Chi [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Grad Inst Biomed Elect & Bioinformat, Taipei 106, Taiwan
关键词
flow rate; high-frame-rate imaging; photoacoustic imaging; nanoparticles; nanorods;
D O I
10.1117/1.2812704
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative flow measurement method that utilizes a sequence of photoacoustic images is described. The method is based on the use of gold nanorods as a contrast agent for photoacoustic imaging. The peak optical absorption wavelength of a gold nanorod depends on its aspect ratio, which can be altered by laser irradiation (we establish a wash-in flow estimation method of this process). The concentration of nanorods with a particular aspect ratio inside a region of interest is affected by both laser-induced shape changes and replenishment of nanorods at a rate determined by the flow velocity. In this study, the concentration is monitored using a custom-designed, high-frame-rate photoacoustic imaging system. This imaging system consists of fiber bundles for wide area laser irradiation, a laser ultrasonic transducer array, and an ultrasound front-end subsystem that allows acoustic data to be acquired simultaneously from 64 transducer elements. Currently, the frame rate of this system is limited by the pulse-repetition frequency of the laser (i.e., 15 Hz). With this system, experimental results from a chicken breast tissue show that flow velocities from 0.125 to 2 mm/s can be measured with an average error of 31.3%. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:9
相关论文
共 40 条
[31]  
Sheppard CW, 1962, BASIC PRINCIPLES TRA
[32]   Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain [J].
Wang, XD ;
Pang, YJ ;
Ku, G ;
Xie, XY ;
Stoica, G ;
Wang, LHV .
NATURE BIOTECHNOLOGY, 2003, 21 (07) :803-806
[33]   Photoacoustic tomography of a nanoshell contrast agent in the in vivo rat brain [J].
Wang, YW ;
Xie, XY ;
Wang, XD ;
Ku, G ;
Gill, KL ;
O'Neal, DP ;
Stoica, G ;
Wang, LV .
NANO LETTERS, 2004, 4 (09) :1689-1692
[34]   Photoacoustic flow measurements with gold nanoparticles [J].
Wei, Chen-Wei ;
Liao, Chao-Kang ;
Tseng, Hsiao-Chien ;
Lin, Yen-Ping ;
Chen, Chia-Chun ;
Li, Pai-Chi .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (10) :1955-1959
[35]  
Wei K, 1998, CIRCULATION, V97, P473
[36]   Interactions between microbubbles and ultrasound: In vitro and in vivo observations [J].
Wei, K ;
Skyba, DM ;
Firschke, C ;
Jayaweera, AR ;
Lindner, JR ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (05) :1081-1088
[37]   Effects of TIPS on liver perfusion measured by dynamic CT [J].
Weidekamm, C ;
Cejna, M ;
Kramer, L ;
Peck-Radosavljevic, M ;
Bader, TR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :505-510
[38]   High-resolution functional vascular assessment with ultrasound [J].
Yeh, CK ;
Ferrara, KW ;
Kruse, DE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (10) :1263-1275
[39]   Feasibility study of time-intensity-based blood flow measurements using deconvolution [J].
Yeh, CK ;
Wang, SW ;
Li, PC .
ULTRASONIC IMAGING, 2001, 23 (02) :90-105
[40]  
Yu YY, 1997, J PHYS CHEM B, V101, P6661, DOI 10.1021/jp971656q