High-resolution functional vascular assessment with ultrasound

被引:22
作者
Yeh, CK
Ferrara, KW
Kruse, DE
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Natl Taiwan Univ, Taipei 10764, Taiwan
关键词
blood flow measurement; high-frequency ultrasound; microcirculation; ultrasound contrast agents;
D O I
10.1109/TMI.2004.834614
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In order to improve the resolution of contrast-assisted imaging systems, we have created a high-frequency destruction/contrast replenishment imaging system with a spatial resolution of 160 mum x 160 mum. The system utilizes a 1-MHz cylindrically focused transducer for destruction and a 25-MHz spherically focused transducer for pulse/echo imaging. Speckle tracking and a clutter filter are applied across frames to remove the challenging physiologic motion artifacts that are obtained when imaging with a mechanically scanned transducer. Using a new estimation technique, flow constants proportional to absolute flow rate were estimated from B-mode time-intensity curves (TICs). The in vitro results indicate a correlation between the actual flow velocity and the estimated rate constant. In vivo images are presented showing blood perfusion in the ciliary processes and iris of the rabbit eye. The regions of interest (ROIs) from the ciliary processes yielded slower perfusion compared with the iris, as expected from vascular casts of the microcirculation in this region. Potential applications of this system include high-resolution perfusion assessment in small animals.
引用
收藏
页码:1263 / 1275
页数:13
相关论文
共 47 条
[1]   40-MHz echocardiography scanner for cardiovascular assessment of mouse embryos [J].
Aristizábal, O ;
Christopher, DA ;
Foster, FS ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (09) :1407-1417
[2]   Optical observation of contrast agent destruction [J].
Chomas, JE ;
Dayton, PA ;
May, D ;
Allen, J ;
Klibanov, A ;
Ferrara, K .
APPLIED PHYSICS LETTERS, 2000, 77 (07) :1056-1058
[3]   Threshold of fragmentation for ultrasonic contrast agents [J].
Chomas, JE ;
Dayton, P ;
May, D ;
Ferrara, K .
JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) :141-150
[4]   Mechanisms of contrast agent destruction [J].
Chomas, JE ;
Dayton, P ;
Allen, J ;
Morgan, K ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :232-248
[5]  
CHOMAS JE, 2001, P IEEE ULTR S, V2, P1713
[6]   A preliminary evaluation of the effects of primary and secondary radiation forces on acoustic contrast agents [J].
Dayton, PA ;
Morgan, KE ;
Klibanov, ALS ;
Brandenburger, G ;
Nightingale, KR ;
Ferrara, KW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1264-1277
[7]   COLOR DOPPLER IMAGING - A NEW NONINVASIVE TECHNIQUE TO DIAGNOSE AND MONITOR CAROTID CAVERNOUS SINUS FISTULAS [J].
FLAHARTY, PM ;
LIEB, WE ;
SERGOTT, RC ;
BOSLEY, TM ;
SAVINO, PJ .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (04) :522-526
[8]  
GIOVAGNORIO F, 1993, J ULTRAS MED, V12, P473
[9]  
Goertz DE, 2002, CANCER RES, V62, P6371
[10]   High-frequency color flow imaging of the microcirculation [J].
Goertz, DE ;
Christopher, DA ;
Yu, JL ;
Kerbel, RS ;
Burns, PN ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (01) :63-71