40-MHz echocardiography scanner for cardiovascular assessment of mouse embryos

被引:68
作者
Aristizábal, O
Christopher, DA
Foster, FS
Turnbull, DH
机构
[1] NYU, Med Ctr, Skirball Inst Biomol Med, New York, NY 10016 USA
[2] NYU, Med Ctr, Dept Radiol, New York, NY 10016 USA
[3] NYU, Med Ctr, Dept Pathol, New York, NY 10016 USA
[4] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Med Biophys, Toronto, ON, Canada
基金
英国医学研究理事会;
关键词
40-MHz echocardiography; ultrasound imaging; Doppler ultrasound; mouse embryo; congenital heart disease;
D O I
10.1016/S0301-5629(98)00132-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Congenital heart disease results from genetic defects that are manifested at early stages of embryogenesis. The mouse is the preferred animal model for studies of mammalian embryonic development and for an increasing number of human disease models. A number of genes identified in the mouse are critical for normal cardiovascular development, but an understanding of the underlying mechanisms regulating heart development is still incomplete, in part because of the lack of methods to measure hemodynamics in live mouse embryos. We describe the development of a 40-MHz ultrasound scanner, which allows image-guided continuous-wave and pulsed Doppler blood flow measurements in mouse embryos, in utero, at the critical early developmental stages. Doppler waveforms acquired from mouse embryonic umbilical vessels, descending aorta, and cardiac ventricles are presented to demonstrate the utility of the method. By combining image-guided ultrasound Doppler with the many available mouse mutants, this approach should lead to new insights into embryonic cardiovascular structure-function relationships. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1407 / 1417
页数:11
相关论文
共 20 条
[1]   Genes and physiology: Molecular physiology in genetically engineered animals [J].
Chien, KR .
JOURNAL OF CLINICAL INVESTIGATION, 1996, 97 (04) :901-909
[2]   A high-frequency continuous-wave Doppler ultrasound system for the detection of blood flow in the microcirculation [J].
Christopher, DA ;
Burns, PN ;
Armstrong, J ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) :1191-1203
[3]   A high-frequency pulsed-wave doppler ultrasound system for the detection and imaging of blood flow in the microcirculation [J].
Christopher, DA ;
Burns, PN ;
Starkoski, BG ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) :997-1015
[4]   ATRIAL-LIKE PHENOTYPE IS ASSOCIATED WITH EMBRYONIC VENTRICULAR FAILURE IN RETINOID-X RECEPTOR-ALPHA -/--MICE [J].
DYSON, E ;
SUCOV, HM ;
KUBALAK, SW ;
SCHMIDSCHONBEIN, GW ;
DELANO, FA ;
EVANS, RM ;
ROSS, J ;
CHIEN, KR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (16) :7386-7390
[5]   Doppler echocardiography of normal and abnormal embryonic mouse heart [J].
Gui, YH ;
Linask, KK ;
Khowsathit, P ;
Huhta, JC .
PEDIATRIC RESEARCH, 1996, 40 (04) :633-642
[6]   TARGETED DISRUPTION OF THE MURINE VCAM1 GENE - ESSENTIAL ROLE OF VCAM-1 IN CHORIOALLANTOIC FUSION AND PLACENTATION [J].
GURTNER, GC ;
DAVIS, V ;
LI, HM ;
MCCOY, MJ ;
SHARPE, A ;
CYBULSKY, MI .
GENES & DEVELOPMENT, 1995, 9 (01) :1-14
[7]  
Kaufman M. H., 1992, ATLAS MOUSE DEV
[8]   In vivo assessment of embryonic cardiovascular dimensions and function in day-10.5 to -14.5 mouse embryos [J].
Keller, BB ;
MacLennan, MJ ;
Tinney, JP ;
Yoshigi, M .
CIRCULATION RESEARCH, 1996, 79 (02) :247-255
[9]  
KWEE L, 1995, DEVELOPMENT, V121, P489
[10]   MEASUREMENT OF THE ULTRASONIC PROPERTIES OF VASCULAR TISSUES AND BLOOD FROM 35-65 MHZ [J].
LOCKWOOD, GR ;
RYAN, LK ;
HUNT, JW ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07) :653-666