High-frequency color flow imaging of the microcirculation

被引:77
作者
Goertz, DE [1 ]
Christopher, DA [1 ]
Yu, JL [1 ]
Kerbel, RS [1 ]
Burns, PN [1 ]
Foster, FS [1 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
英国医学研究理事会;
关键词
color Doppler imaging; color flow mapping; Doppler ultrasound; high-frequency ultrasound; microcirculation; blood velocity; blood flow; microvascular morphology; angiogenesis;
D O I
10.1016/S0301-5629(99)00101-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The extension of ultrasound (US) color flow imaging (CFI) techniques to high frequencies ( > 20 MHz) has the potential to provide valuable noninvasive tools for scientific and clinical investigations of blood dow in the microcirculation. We describe the development of a slow-scan CFI system operating in the 20-100-MHz range that has been optimized to image the microcirculation, The apparatus has incorporated elements of a previously reported pulsed-wave Doppler system and is capable of operating in either CFI or pulsed-wave mode. The performance of the CFI system was evaluated at a center frequency of 50 MHz using two PVDF transducers with -6-dB beam widths of 43 and 60 mu m. The -6 dB-axial resolutions were estimated to be 66 and 72 mu m, respectively. In vivo validation experiments conducted using the murine ear model demonstrated the detection of flow in vessels down to 15-20 mu m in diameter with how velocities on the order of mm per s, Further experiments examining experimental murine tumors confirmed the successful detection of dow in the tumor microcirculation, (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 31 条
[1]   THE HAIRLESS MOUSE EAR FOR INVIVO STUDIES OF SKIN MICROCIRCULATION [J].
BARKER, JH ;
HAMMERSEN, F ;
BONDAR, I ;
UHL, E ;
GALLA, TJ ;
MENGER, MD ;
MESSMER, K .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 83 (06) :948-959
[3]   INITIALIZATION FOR IMPROVED IIR FILTER PERFORMANCE [J].
CHORNOBOY, ES .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1992, 40 (03) :543-550
[4]   A high-frequency pulsed-wave doppler ultrasound system for the detection and imaging of blood flow in the microcirculation [J].
Christopher, DA ;
Burns, PN ;
Starkoski, BG ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) :997-1015
[5]  
CHRISTOPHER DA, 1998, THESIS U TORONTO TOR
[6]   MODEL PREDICTING SURVIVAL IN STAGE-I MELANOMA BASED ON TUMOR PROGRESSION [J].
CLARK, WH ;
ELDER, DE ;
GUERRY, D ;
BRAITMAN, LE ;
TROCK, BJ ;
SCHULTZ, D ;
SYNNESTVEDT, M ;
HALPERN, AC .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1989, 81 (24) :1893-1904
[7]  
DEKRRON M, 1993, THESIS ERASMUS U ROT
[8]   Color flow mapping [J].
Ferrara, K ;
DeAngelis, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :321-345
[9]   Estimation of blood velocity with high frequency ultrasound [J].
Ferrara, KW ;
Zagar, BG ;
SokilMelgar, JB ;
Silverman, RH ;
Aslanidis, IM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (01) :149-157
[10]   A NEW WIDE-BAND SPREAD TARGET MAXIMUM-LIKELIHOOD ESTIMATOR FOR BLOOD VELOCITY ESTIMATION .1. THEORY [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :1-16